User manual
NTD Clocks User Manual - Rev 2.2.2 Jan-10
29
© Masterclock
®
, Inc
Set Digital Display Intensity
The digital clock display intensity is controlled with a scale of 1 to 14 with 14 being brightest. Enter the
value for the desired intensity setting.
Set Digital Display Type
Allows configuration for time display (12 and 24 hour) for 4 and 6 digit clocks, or date display
(MM/DD/YY or DD/MM/YY) for 6 digit clocks.
Set Digital Display Options
The digital clock display special options may be adjusted. This includes displaying dashes when an
NTP timeserver is not present along with a delay function to display the dashes.
Set Analog Clock Hourly/Twice Daily Correction
[Note: This menu item feature has been retained for backward compatibility with a discontinued model
of analog clock with AC synchronous only. This feature does not apply to the stepper motor analog
clock, or digital clocks.]
Soft Reset
The network clock may be restarted with a soft reset command to allow the device to clear its current
communications buffer and re-initialize its processing, includes re-requesting of a DHCP address. This
feature is intended to allow the user to remotely attempt to clear issues with the unit. This feature does
not restore the unit to its factory default state. This command is essentially equivalent to the right click
menu item “Reset Device” under WinDiscovery and the automatic soft restart built into the clock.
Reset Configuration
The network clock may be reset from telnet. Use this command sparingly as it will reset the unit to
initialize and utilize DHCP IP addressing mode by default, and will likely change the IP address of the
unit, making the communication via telnet impossible until the new IP address of the unit is configured
or known.
If this command fails to clear an issue with the clock, a hard reset may be in order to return the unit to its
factory default state. In certain [rare] instances it may become necessary to access the configuration
reset switch to return the network clock to its factory default settings or to recover from a non-
responsive condition. Consult the section “Reset Factory-Default Configuration” under the
“Configuration” section of this manual.
Set stepper hand position analog clock
[Note: this menu items applies to analog stepper motor models only.]
Get Status stepper analog clock
Provides status information specific to the analog stepper motor clock.
[Note: this menu items applies to analog stepper motor models only]