User manual
Masterclock NTD200 Series User Manual – v1 – January 2014
7
TIME ZONE OFFSETS
The NTD200 digital time display maintains time as UTC
initially. A Time Zone offset or bias can be provided to adjust
the time for display purposes. A bias can be set as a positive
(+) or negative (-) value. Expect a resolution of one second.
DAYLIGHT SAVING TIME
An automatic Daylight Saving Time (DST) adjustment can be
configured separately and in addition to a Time Zone offset.
U.S. STANDARD
DST begins on the second Sunday of March at 2:00 AM (Local
Time) and ends the first Sunday of November at 2:00 AM
(Local Time).
EU STANDARD – EUROPEAN UNION
In the European Union, daylight change times are defined
relative to the UTC time of day. Summertime Period begins at
1:00 AM, UTC on the last Sunday of March and ends at 1:00
AM, UTC on the last Sunday of October.
FREEWHEELING ACCURACY
The NTD200 has built-in provisions to allow it to freewheel
and maintain accuracy for extended periods in the absence of
NTP. These features also allow the unit to be set manually
and run without NTP with precision.
TCXO AND RTC CIRCUIT
The NTD200 contains a precision TCXO (Temperature
Compensated Crystal Oscillator) and RTC (Real Time Clock)
circuit allowing the clock to maintain an accuracy of ± 1
minute per year to the last known NTP input (±165 mSec per
day) when NTP is not present or cannot be decoded (i.e.
freewheeling mode)
MAINTENANCE-FREE RECHARGEABLE BATTERY
The RTC and TCXO are maintained continuously from a
rechargeable battery circuit during periods of power outage.
Minimum holdover period is one year with a fully-charged
battery under constant drain.
If the Time Code input is different from
UTC, do not adjust the Time Zone and/or
DST offset. These will adjust automatically.
European customers: Please carefully
consult the section entitled “Device
Settings” for details on setting your
“Summertime Period.”
Daylight Savings Time (DST) adjustments
must be configured using the daylight time
option and not with the Time Zone offset
option in order to ensure proper year-
around operation.