User manual

CLKTCDSeriesUserManualRev.2.0.1Page21
DIPswitchbank2(S2)configureshowTimeCodeControlBits/Fieldsarehandled.
S2.1andS2.2
TimecodeControlBitsorControlFields
HouroffsetS2.1 S2.2
Noadditionalencoding OFF OFF (default)
IRIG1344&SMPTELeitch ON OFF
Reservedforfutureuse OFF ON
Reservedforfutureuse ON ON
S2.3andS2.4
Controlthefaceplateilluminationlevel,ifyourclockhasthisoptioninstalled.
IlluminationLevel(Brightness) S2.3 S2.4
0%OFF OFF (default)
35%ON OFF
70% OFF ON
100%ON ON
S2.5
Thisswitchiscurrentlyundefinedandreservedforfutureuse.
Function S2.5
Reserved OFF (default)
Reserved ON
S2.6
Setthesecondhandmotionmode
Function S2.6
Sweep(continuous) OFF (default)
Step(pulse) ON
S2.7
Calibratehandstoposition.UsedinconjunctionwithS2.8“ON”tosettheclockhands
Function S2.7
Setto12:00:00 OFF (default)
Setto6:00:00 ON
S2.8
UsedinconjunctionwithS2.7tosettheclockhands
Function S2.7
RunOFF (default)
SetON
OncetheclockhasbeenconfiguredwiththeCLKTCDSetsoftware,theswitchsettingswillbe
overriddenandtheunitwillignoreallswitchsettingsuntilit’sresettofactorydefault.