Installation manual

__________________________________________________________________________________________________
__________________________________________________________________________________________________
Operator Manual for MC-4044 Series 5 G/93040 Issue 6 Page 7
AUTO REDIAL * 69 "69 is n, please enter command"
Redial if diversion number is busy
1 1
Connect if diversion number is busy 2 2
DIAL TONE DETECT * 70 "70 is n, please enter command"
5 sec wait for dial tone
and re-loop if none
1 1
3 sec wait for dial tone (blind dial) 2 2
Band width limited dial tone detect 3 3
CONTINUOUS TONE DISCONNECT * 71 "71 is n, please enter command"
Keep connection on continuous tone
1 1
Disconnect on continuous tone 2 2
LINE TEST FOR DISCONNECTION * 72 "72 is n, please enter command"
Loop break every 10 seconds of silence 1 1
No loop break
2 2
TIME BETWEEN TRIES (2 No TRY) * 73 "73 is n, please enter command"
n x 6 secs (eg. 4
x 6 = 24 secs) 4 4 (In increments of 6 s up to 54 s)
SPARE * 74 "74 is n, please enter command"
Not currently used 0 0
CALL PROGRESS TEST NUMBERS * 75 "75 is n, please enter command"
Off
1 1
On 2 2
CPC (LOOP CURRENT LOSS/LINE REVERSAL DETECT) * 76 "76 is n, please enter command"
Yes - for connect and disconnect 1 1
No 2 2
Yes
- for disconnect only 3 3
Yes - for connect only 4 4
Yes - hang up on any CPC, L1 or L2 5 5
ROA mandatory detect for call connection 6 6
ERROR MESSAGE NUMBERS * 77 "77 is n, please enter command"
Off
1 1
On 2 2
PHASE LOCK LOOP DECODER * 78 "78 is n, please enter command"
On 1 1
Off
2 2
BUSY COUNT FOR DISCONNECTION * 79 "79 is n, please enter command"
1-8 bursts 7 7
MAX. RING VOLTAGE OFF TIME * 80 "80 is n, please enter command"
1-8 Seconds 4 4
RANDOM BUSY DETECT * 81 "81 is n, please enter command"
Yes
1 1
No 2 2
HOOK FLASH * 82 "82 is n, please enter command"
100 ms
1 1
250 ms 2 2
500 ms 3 3
1000 ms 4 4