Installation manual

__________________________________________________________________________________________________
__________________________________________________________________________________________________
Operator Manual for MC-4044 Series 5 G/93040 Issue 6 Page 21
TONE DETECTION CODES
Using either the MASTERCALL keypad or by Remote Control, enter Tone Detection access code * 67 05 #, listen for
"Please enter command"
COMMANDS
* nn where nn is tone parameter code number
nnn = entry
# = scroll down to next tone parameter
* * = abandon (do not save any changes)
* # = store (save any changes)
After either storing or abandoning program changes you can continue to make other programming changes, press # # to
end, or simply hang up.
________________________________________ AUSTRALIA
TONE PARAMETER CODE VALUE RESPONSE
DISCONNECT CODE
* 21 0-9, 11-18 (See below) "21 is nnn, enter command"
______________________________________________________________________________
Disconnect Codes
001 Busy tone
002 Dial tone
003 Number Unobtainable tone
005 Continuous tone
006 Random busy tone
007 Ring tone
008 Not Used
009 Not Used
000 Silence
011 Random busy tone
012 Stop Task
013 Loop current loss / line reversal detect
014 Forced disconnect (# 59 # from user)
015 Silence
016 Continuous tone
017 In band tone (350 - 500 Hz)
018 Total time limit exceeded
255 Don’t know