Operator Manual for MC-4044 Series 5 G/93040 Issue 6 Page 10
AMPLIFIER
PARAMETER CODE DEFAULT VALUE RESPONSE
Entry
WAIT FOR DIAL TONE IN SECONDS
* 16 005 (seconds) "16 is nnn, enter command"
DTMF Tx LEVEL
* 17 000 (flat) "17 is nnn, enter command"
SPEECH CONNECT SENSITIVITY - Transitions prior to valid ring tone
* 18 005 (transitions) "18 is nnn, enter command"
SPEECH CONNECT SENSITIVITY - Accumulated signal length of transitions in ms/32
* 19 018 (ms/32) "19 is nnn, enter command"
SPEECH CONNECT SENSITIVITY - Transitions during valid ring tone
* 20 006 (transitions) "20 is nnn, enter command"
DISCONNECT CODE
* 21 0-9, 11-18 (Consult factory) "21 is nnn, enter command"
TONE DETECTOR SENSITIVITY (range 20 - 60) (Increasing value de
creases sensitivity)
* 22 030 "22 is nnn, enter command"
BACKGROUND NOISE REJECTION (range 20 - 60) (Increasing value increases rejection, decrease for fax/data)
* 23 050 "23 is nnn, enter command"
TOTAL DIAL ATTEMPTS
* 26 008 "26 is nnn, enter command"
OUTPUT LEVEL LINE 2 (‘OUT’) (range 034 - 063) (Increasing value increases output level)
* 27 048 "27 is nnn, enter command"
OUTPUT LEVEL LINE 1 (‘IN’) (range 034 - 063) (Increasing value increases output level)
* 28 048 "28 is nnn, enter command"
DUPLEX GAIN (range 20 - 36) (Increasing value increases duplex gain)
* 29 038 "29 is nnn, enter command"
AGC OUTPUT LEVEL (000 = off, range 060 - 100) (Increasing value increases automatic gain control)
* 30 000 "30 is nnn, enter command"