Installation guide

__________________________________________________________________________________________________
Technical Guide for Office Extender T/95081 Issue 5 Page 4
__________________________________________________________________________________________________
AMPLIFIER PARAMETER CODE DEFAULT VALUE RESPONSE
SPARE
* 16 000 16 is nnn, enter command
DTMF Tx LEVEL
* 17 010 (000 = Off, 063 - 001) 17 is nnn, enter command
SPEECH CONNECT SENSITIVITY - Transitions prior to valid ring tone
* 18 005 (transitions) 18 is nnn, enter command
SPEECH CONNECT SENSITIVITY - Accumulated signal length of transitions in ms/32
* 19 018 (ms/32) 19 is nnn, enter command
SPEECH CONNECT SENSITIVITY - Transitions during valid ring tone
* 20 006 (transitions) 20 is nnn, enter command
DISCONNECT CODE
* 21 0-9, 11-18 (Consult factory) 21 is nnn, enter command
TONE DETECTOR SENSITIVITY (range 20 - 60) (Increasing value de
creases sensitivity)
* 22 030 22 is nnn, enter command
BACKGROUND NOISE REJECTION (range 20 - 60) (Increasing value increases rejection, decrease for fax/data)
* 23 050 23 is nnn, enter command
OUTPUT LEVEL LINE 2 (‘OUT’) (range 034 - 063) (Increasing value increases output level)
* 27 042 27 is nnn, enter command
OUTPUT LEVEL LINE 1 (‘IN’) (range 034 - 063) (Increasing value increases output level)
* 28 042 28 is nnn, enter command
DUPLEX GAIN (range 20 - 40) (Increasing value increases duplex gain)
* 29 036 29 is nnn, enter command
AGC OUTPUT LEVEL (000 = off, range 060 - 100) (Increasing value increases automatic gain control)
* 30 000 30 is nnn, enter command