REGULATOR, BURNER AND GAS VALVE CONNECTION & OPERATION
• Inspect hose before each use. If there are signs of abrasion, wear, cuts, or leaks, the hose must
be replaced. DO NOT USE.
• Inspect burner before each use. Check burner and burner venturi tube for insects and insect
nests. A clogged tube can lead to a re beneath unit.
• Check to ensure the orice is centered inside the venturi tube. Failure to properly assemble
the valve orice to the venture tube can result in gas leak or potential re at connection. See
assembly steps for proper assembly method.
•
Check to ensure the igniter pin is properly spaced and aligned to the burner. Igniter pin should
be approximately 1/4” from the burner and aligned to the top of a burner port (Fig. 2). Conrm
spacing is correct by pressing the igniter button and ensuring spark occurs between igniter pin
and burner.
• Connect hose regulator to LP Gas Cylinder (Fig. 1)
1. Make sure gas cylinder valve is closed. Turn valve clockwise until it stops.
2. Make sure burner control valve on smoker is in the OFF position.
3. Remove protective cap from gas cylinder and coupling nut if applicable.
4.
Center and insert regulator nipple into valve outlet on gas cylinder as shown in gure on the left.
Turn regulator coupling nut counter clockwise until it stops. DO NOT OVER TIGHTEN.
• Perform soapy water test.
• Before starting lighting procedure make sure the smoker door(s) are open.
• When lighting burner remove all parts inside or on unit to prevent explosion from gas build up.
• To use, turn gas cylinder valve ON, push control knob in, hold and and turn counter-clockwise
to desired temperature setting. Push ignitor button to light, after ignition continue holding control
knob in for 5 seconds to activate the ame sensor.
• If ignition does not take place within ve seconds, turn control knob to OFF position and wait ve
minutes and repeat lighting procedures. If ignition still does not occur, see match light instructions.
• Always ensure that smoker door(s) are open before igniting. Gas can accumulate in smoker.
• If ame goes out during cooking, turn control knob OFF, turn gas cylinder valve OFF, wait 5
minutes, then open door(s) and wait 5 additional minutes before repeating ignition instructions
above.
• Control knob sets the smoker to a desired temperature. Push control knob in and turn clockwise
to shut ame o.
• Visually check burner ame (Fig. 3). A CORRECT FLAME should be blue with a small amount of
yellow at the tip. An INCORRECT FLAME is excessively yellow and irregular. If an incorrect ame
occurs, turn control knob to OFF position, turn OFF gas cylinder valve. Allow unit to cool then
loosen shutter screw and adjust air shutter (Fig. 4). If an incorrect ame still occurs allow unit to
cool and then clean burner. Let burner completely dry before re-lighting.
• After use turn control knob OFF, then turn gas cylinder valve OFF and disconnect tank.