User Manual

8
Emergency Cause Possible Solution
Gas leaking from cracked, cut or
burned hose
Damaged hose Turn o gas at LP cylinder.
Replace hose.
Contact Customer Service at 1300 174 876.
Gas leaking from LP cylinder Failure due to rust or mishandled equipment Replace LP cylinder.
Gas leaking from gas cylinder valve Failure of valve due to rust, mechanical
failure or mishandled equipment
Turn o gas cylinder valve and return
cylinder to gas provider/supplier.
Gas leaking between LP cylinder
and regulator connection
Improper installation, connection not tight
enough, damaged threads or bad rubber seal
Turn o gas cylinder valve, then re-attach
regulator to cylinder.
Turn o gas cylinder valve and return
cylinder to gas provider/supplier.
Visually inspect rubber seal for damage.
Fire under control panel Fire in tube of burner due to burner blockage
Turn o both burner control knob and gas
cylinder valve. Once the re is out and
burner has cooled, remove and inspect
burner for spiders, nests, rust or other debris.
Grease re or excessive/
continuous ame
Grease build up on or around burner area
Turn o both burner control knob and gas
cylinder valve. Allow ames to extinguish
and time for unit to cool down. Clean grease/
food particles from/around burner or burner
area and surrounding surfaces.
WARNING
In the event of a gas leak that cannot be stopped, or if a
re occurs due to a gas leak, contact the re department.
MATCH LIGHT INSTRUCTIONS
1. Read all instructions and warnings before lighting.
2. Check control knob and gas cylinder valve to be certain it is
in OFF position before connecting to gas cylinder.
3. Perform soapy water test before each use.
4. Open door(s) during lighting and/or remove all accessories
and cooking vessels from in/or on unit.
5. Turn gas cylinder valve ON, push control knob in, hold and
and turn counter-clockwise to desired temperature setting,
after ignition continue holding control knob in for 5 seconds to
activate the ame sensor.
6. Place a long, lit replace match stick close enough to burner
to ignite.
7. If ignition does not take place within ve seconds, turn control
knob to OFF position and wait ve minutes and repeat match
light instructions.
8. After each use, rst turn control knob o, then gas cylinder
valve o. Always allow unit to cool completely before
touching, moving or storing.