Technical data

72
Manual – MOVI-PLC® advanced DH.41B Controller
6
Structure of the DP-V1 parameter channel
PROFIBUS-DP-V1 Functions
MOVILINK
®
return
codes of
parameter setting
for DP-V1
The following table shows the return codes that are returned by the SEW DP-V1
interface in case of an error in the DP-V1 parameter access.
MOVILINK
®
Return code (hex)
Description
0x0810 Invalid index, parameter index does not exist in the unit
0x0811 Function / parameter not implemented
0x0812 Read access only
0x0813 Parameter lock activated
0x0814 Factory setting is active
0x0815 Value for parameter too large
0x0816 Value for parameter too small
0x0817 Reserved
0x0818 Error in system software
0x0819 Reserved
0x081A Parameter access only via RS485 interface
0x081B Parameter is access-protected
0x081C Reserved
0x081D Invalid value for parameter
0x081E Factory setting was activated
0x081F Reserved
0x0820 Reserved
0x0821 Reserved
0x0822 Reserved
0x0823 Reserved
0x0824 Reserved
0x0505 Incorrect coding of management and reserved byte
0x0602 Reserved
0x0502 Reserved