Technical data

48
Manual – MOVI-PLC® advanced DH.41B Controller
4
Configuration for a PROFIBUS DP master
Configuration and Startup
Configuration
examples
Slot 1: Empty
Slot 2: Param (4 words)
Slot 3: 10 PD
Configuration telegram sent to the MOVI-PLC
®
advanced DHF41B control card: 0x00
0xC0 0xC87 0x87 0xC0 0xC9 0xC9
Universal DP con-
figuration
After selecting the "Universal Module" DP configuration (S7 HW Config), you can
structure the DP configuration individually, although the following conditions must be
complied with:
Module 0 (DP identifier 0) defines the parameter channel of the control card.
To ensure the parameter settings are made correctly, you must always transfer the
parameter channel consistently for the entire length.
Module 1 (DP identifier 1) defines the process data channel of the control card.
In addition to the process data configurations predefined in the GSD file, you can also
specify process data configurations with 4, 5, 7, 8 and 9 process data words. Ensure that
the number of input and output words is always the same. If the lengths are different,
data cannot be exchanged. In this case, the Profibus Fault LED will continue to flash.
16 PD Process data exchange via
16 process data words
0xC0, 0xCF, 0xCF
32 PD Process data exchange via
32 process data words
0xC0, 0xDF, 0xDF
Process Data
configuration
Meaning / notes DP configuration
Length Function
0 Parameter channel deactivated
8 I/O bytes or 4 I/O words Parameter channel is used
Length Function
2 I/O bytes or 1 I/O word 1 process data word
4 I/O bytes or 2 I/O words 2 process data words
6 I/O bytes or 3 I/O words 3 process data words
8 I/O bytes or 4 I/O words 4 process data words
10 I/O bytes or 5 I/O words 5 process data words
12 I/O bytes or 6 I/O words 6 process data words
14 I/O bytes or 7 I/O words 7 process data words
16 I/O bytes or 8 I/O words 8 process data words
18 I/O bytes or 9 I/O words 9 process data words
20 I/O bytes or 10 I/O words 10 process data words
00
I