Technical data
Manual – MOVI-PLC® advanced DH.41B Controller
37
4
Configuration with the MOVITOOLS® MotionStudio PC software
Configuration and Startup
• Set the IP address of the PC interface:
– Under [Start] / [Settings] / [Network connections], choose the PC interface you
require and select the properties window of the PC interface from the context
menu.
– In the properties of the "Internet protocol (TCP/IP)" option, select the entry "Use
following IP address".
– Enter the net mask that is set in the MOVI-PLC
®
advanced DH.41B control card
(e.g. 255.255.255.0 when DIP switch S1 is in the top position).
– Set the IP address depending on the net mask. The IP addresses of the
MOVI-PLC
®
advanced DH.41B control card (Ethernet 2) and the PC interface
must differ with the exception of the areas defined by the net mask. In the area
defined by the net mask, the IP addresses have to be identical. Do not set the last
byte of the IP address to either 0 or 255.
Example:
In this example, the last 8 bits of the IP address of the MOVI-PLC
®
advanced
DH.41B control card and the PC interface must differ.
Address settings
for engineering
access via a
network
Proceed as follows to establish engineering access to the MOVI-PLC
®
advanced
DH.41B control card via an existing network:
• In the <Ethernet2...> section of the NetConfig.cfg configuration file in the "System"
folder of the SD memory card, enter the following data in accordance with the
specifications of your network administration:
– IP address
–Net mask
– Gateway address
• Change DIP switch S1 to the bottom position. Doing so makes sure that the new ad-
dress settings will take effect when the MOVI-PLC
®
advanced DH.41B control card
is restarted.
Net mask
Decimal Binary
255.255.255.0 11111111.11111111.11111111.00000000
00
I