Installing option DH.41B in MOVITRAC® B / compact controller
Assembly / Installation Notes
3.7 Installing option DH.41B in MOVITRAC
®
B / compact controller
3.7.1 Functional description of the terminals and LEDs
3.7.2 Connecting the RS485 interface COM 1 (terminal X24)
Terminals X24 and X34:1/3/5 are connected in parallel. You can connect a DOP11A op-
erating terminal at X24. If X24 is not occupied, you can connect an operating terminal or
a MOVIMOT
®
gearmotor with integrated frequency inverter at X34:1/3/5.
See section 3.4.5. for additional information.
The MOVI-PLC
®
advanced DH.41B control card is installed as specified in section 3.4.
The MOVITRAC
®
B and compact controller option slots provide additional connections
and operating displays for the MOVI-PLC
®
advanced DH.41B control card. They are
described in the following section.
Front view
MOVITRAC
®
B / com-
pact controller
Designation
LED
Terminal
Function
58905AXX
LED H1
H2
System error
Reserved
Connector X24:
RS485 COM 1
(RJ10 socket)
X24:4
X24:3
X24:2
X24:1
DGND
RS–
RS+
5 V
Reference potential COM 1
Signal RS485–
Signal RS485+
Voltage output DC+5 V
Side view
Compact controller
Designation Terminal Function
58906AXX
Connector X26:
CAN 1 and
voltage supply
(plug-in terminal)
X26:1
X24:2
X24:3
X24:4
X26:5
X26:6
X26:7
CAN1H
CAN1L
DGND
Reserved
Reserved
DGND
DC 24 V
System bus CAN1 High
System bus CAN1 Low
Reference potential control / CAN1
-
-
Reference potential control / CAN1
Voltage supply control
X2
4
H1
H2
2345671
X26