Technical data
12
Manual – MOVI-PLC® advanced DH.41B Controller
3
Installation options for the MOVI-PLC® advanced DH.41B control card
Assembly / Installation Notes
3 Assembly / Installation Notes
3.1 Installation options for the MOVI-PLC
®
advanced DH.41B control card
Observe the following installation instructions:
3.2 Installing MOVI-PLC
®
advanced DH.41B in MOVIDRIVE
®
MDX61B
Plug the MOVI-PLC
®
advanced DH.41B control card into the fieldbus slot or expansion
slot on MOVIDRIVE
®
MDX61B.
Before you begin Observe the following notes before installing or removing the MOVI-PLC®
advanced DH.41B control card:
• Disconnect the drive inverter from the power. Switch off the DC 24 V and the supply
voltage.
• Take appropriate measures to protect the MOVI-PLC
®
advanced DH.41B control
card from electrostatic charge (discharge strap, conductive shoes, etc.) before
touching it.
• Remove the keypad and front cover before installing the MOVI-PLC
®
advanced
DH.41B controller.
• Replace the front cover and keypad after installing the MOVI-PLC
®
advanced
DH.41B control card.
• Keep the MOVI-PLC
®
advanced DH.41B control card in its original packaging until
immediately before you are ready to install it.
• Only touch the edges of the MOVI-PLC
®
advanced DH.41B control card. Do not
touch any of the components.
• Never put MOVI-PLC
®
advanced DH.41B down on a conductive surface.
• You can plug the MOVI-PLC® advanced DH.41B control card into the
MOVIDRIVE® MDX61B drive inverter, but never into the MOVIDRIVE® MDX60B
drive inverter.
• Option cards can only be installed or removed for MOVIDRIVE® MDX61B drive
inverters sizes 1 to 6.
• Only SEW-EURODRIVE engineers may install or remove option cards for
MOVIDRIVE® MDX61B size 0 drive inverters.
• Only SEW-EURODRIVE engineers may install or remove the MOVI-PLC®
advanced DH.41B control card in MOVIAXIS® or assemble a MOVI-PLC®
DH.41B/UOH..B compact controller.