Technical data

Manual – MOVI-PLC® advanced DH.41B Controller
11
2
MOVI-PLC® advanced DH.41B control card
Introduction
RS485 interfaces
COM1 and COM2
Connect one of the following devices to RS485 interface COM1 or COM2:
DOP11A operator terminal
MOVIMOT
®
gearmotor with integrated frequency inverter
Binary inputs and
outputs
Binary inputs and outputs enable you to switch actuators (e.g. valves) and evaluate
binary input signals (e.g. sensors) You can use binary inputs and outputs as required
when programming in the PLC editor of the MOVITOOLS
®
MotionStudio software.
Diagnostics The LEDs of the MOVI-PLC
®
advanced DH.41B control card indicates the following
status:
Voltage supply of the binary inputs and outputs
General status of the MOVI-PLC
®
advanced DH.41B control card
Status of the control program
Status of the PROFIBUS interface
Status of the DeviceNet interface
Status of both CAN interfaces
You can connect operator terminals to perform diagnostics. We recommend connecting
the operator terminal to the RS485 interface. Connection to the CAN 1 or CAN 2 inter-
face is in preparation.