Issue: 2 THE BLACK PROVAC BACK PACK VACUUM CLEANER OPERATOR AND PARTS MANUAL Model: BLACK PROVAC Model No: PROBFT1000 Safety approval No: NSW21128 EMC Approval No: N14590 Serial No:________________ Before using machine: For Safety - Read all safety and operator instructions Master Australia Pty Ltd 45 Marrickville Rd Marrickville NSW 2204 Ph: 612 9550 5800 • Fax: 612 9550 5876
1
CONTENTS IMPORTANT SAFETY PRECAUTIONS_____________________________________________________________________3 MODIFICATIONS________________________________________________________________________________________4 MACHINE INSTALLATION ____________________________________________________________________________4/5 Machine contents Machine assembly MACHINE OPERATION __________________________________________________________________________________5 STORING MACHINE ________________________________________________
INTRODUCTION IMPORTANT SAFETY INSTRUCTIONS! Your new Provac Backvac Vacuum Cleaner is designed for the professional daily maintenance of carpets and hard floors. Your Provac vacuum cleaner has been built with quality and reliability in mind. If the safety precautions and maintenance instructions are followed, you will enjoy many years of trouble free operation.
WARNING: Hazardous Voltage. Shock or electrocution can result. Unplugging machine before servicing IS A MUST. MODIFICATIONS - REPAIRS OR SERVICING Only original parts and accessories are to be used. Failure to adhere to these recommendations could result in machine failure and damage that will not be covered by the appliance warranty. Damaged equipment could also result in injury to persons.
WARNING: Hazardous Voltage. Shock or electrocution can result. Unplug machine before servicing. 2. ASSEMBLY OF MACHINE Cloth filter bag and secondary filter: • Twist the lid anti-clockwise to expose inside bag compartment. Be sure that the vacuum filter bag and secondary filter are inside the bag compartment before vacuuming. Close lid. MACHINE OPERATION FOR SAFETY: Do not operate machine unless operator manual is read and understood. 1.
PROVAC COMFORT FIT PROCEDURE NOTE: CONDUCT THE PRE START CHECK LIST BEFORE BEGINNING THIS PROCEDURE 1. Loosen both shoulder straps to make it easier to fit the back pack. 1 2 3 4 5 6 7 8 2. Lift the back pack while sliding one arm through the shoulder harness. Slide the other arm through the second shoulder harness. 3. Loosen the shoulder harnesses before buckling the waist strap, so the weight of the unit is sitting comfortably on the waist. 4–5.
InstaSwap REPLACING THE POWER LEAD, SHOULDER PADS AND WAIST BELT Removing the power lead: 1. Disconnect the connector plug from the machine. Installing the power lead: 1. Feed approximately 45cm of lead between back support and lower body, then connect plug into the socket. Removing the shoulder straps: 1. Remove shoulder adjustment strap from the buckle and loop on the shoulder pad. Installing the shoulder straps: 1. Start with the shoulder pad loop entering the handle area.
PROBFT1000 BLACK PROVAC 1 14 15 2 16 3 17 4 18 19 5 21 6 20 7 8 9 22 10 23 24 11 25 26 12 27 28 13 8
PROVAC PARTS LIST - PROBFT1000 1 2 3 4 5 6 7 l 8 l 9 10 11 12 13 14 15 16 17 l 18 l 19 l 20 21 22 l 23 l 24 25 l 26 27 28 Lid - incl. locking ring Filter dust Bag Secondary filter Body Exhaust filter - set Motor gasket - flo through Vac motor - 1000W, 2 stage, flo through EMC - RFI capacitor Thermal cut out - NOT SHOWN Carbon brush set, self interrupting Motor retaining plate Insulation set - lower body & base Bumper Base end cap - for flo thru motor Power lead - 15 metre, 7.
WIRING DIAGRAM BLACK MOTOR THERMAL CUT OUT CAPACITOR RFI BLACK A BROWN N BLUE POWER INLET SOCKET SWITCH POWER OUTLET SOCKET A BROWN N BLUE MAINTENANCE ADVICE WARNING: Always disconnect the plug from the main supply before commencing any cleaning or maintenance of the machine. Always refer to the manufacturers technical data and instructions when replacing any parts DAILY INSPECTION 3 MONTH MAINTENANCE • Refer attached pre start check list.
DAILY START & FINISH CHECK LIST WARNING: HAZARDOUS VOLTAGE - SHOCK OR ELECTROCUTION CAN RESULT FROM USING MACHINE WITH DAMAGED CORD 1 Check power lead and plug. Replace damaged cord before using machine. 2 Check the dust bag is empty. Clean it if necessary before and after vacuuming. 3 Check the secondary filter. Replace or clean filter as necessary. 4 Check floor tool, vacuum hose and connector for damage or blockage.
TROUBLE SHOOTING GUIDE PROBLEM • Machine does not operate • Poor Vacuuming Performance • Noisey vacuum motor POSSIBLE CAUSE SOLUTION Plug loose on machine Push in plug Faulty vacuum motor Contact service centre Faulty power cord Replace power cord Faulty power switch Contact service centre Blocked hose, wand or floor tool Clean out hose, wand or floor tool Full bag Empty out bag Worn out cloth bag Replace bag Clogged secondary filter Replace secondary filter Faulty vacuum motor Contact
WARRANTY STATEMENT Master Australia Pty Ltd warrants it's products against manufacturers defects in material and workmanship for a period of 12 months, including labour, from date of original purchase, to the original purchaser. Should a component fail within the warranty period, Master Australia Pty Ltd or its Authorised Service Agent: 1. Will evaluate the defective component to establish the reason for failure 2.
NOTES: _________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ __________________________
Master Australia Pty Ltd 45 Marrickville Rd Marrickville NSW 2204 Ph: 612 9550 5800 • Fax: 612 9550 5876