Owner`s manual
Page 21 Bullfrog Spas Owner’s Manual
seconds and “SET START FILTER 1” (AM cycle) will
appear on the display.
Press the “Warmer” or “Cooler” button to reset the
filter start time.
Next, press the “*” button and when “SET HEAT” is on
the display, press the “Warmer” (on) button to heat the
water during filtering, or press the “Cooler” (off)
button to disable the heater during filtering.
Press the “*” to see “STOP FILTER 1” and then adjust
the stop time with the “Warmer” or “Cooler” buttons as
done above.
Press the “*” button to see “START FILTER 2” (PM cycle)
and proceed as above.
Pressing the “#” button will enter the new filter cycle
times into the system and complete the filter
programming.
Ozone Sterilizer (optional): For safety purposes, your
Ozone Sterilizer is disabled for a 30 minute period
whenever a “Jets” button is pressed.
SAFETY/FEATURE MESSAGES:
Battery Backup (no message on display)
When power has been cut off from the spa, the Master
Control Pad will use its 30-day battery backup to
preserve its settings. When this occurs, the Control
Pad will be disabled until power is restored to the spa.
Economy Mode
The spa is in economy mode. "Econ" is flashed
alternately with the current temperature and "COOL"
until the spa water is less that 15°F cooler than the set
temperature.
Overheat Protection (Spa is Deactivated.)
DO NOT ENTER THE WATER. If a malfunction occurs
and the spa water has reached 112°F, the display will
flash “OH” (meaning over-heat) and the system will
completely shut down. Remove the cover to cool the
water. Overheating may also occur if the filter
duration is set too long. At 110°F, the spa should
reset itself. If the high-limit sensor detects 118°F at
the heater, the spa will shut down. When the heater
cools to 110°F, press any button to reset the spa. If
the spa will not reset, then shut off power to the spa
and contact your authorized Bullfrog Spa Dealer.
Flow Switch Detection
If the panel display is flashing “FLO” (meaning flow)
alternately with Temperature, one of the following
may have occurred:
1- The filter may be plugged. Remove the filter and
clean.