Error Messages ( Continued )
“FC” Freeze Condition
The System checks the water temperature for a reading at or below 55ºF(12ºC). If an error is
detected, the topside control will display the code “FC”. This means a potential freeze condition
has been detected (the spa temp is below 55ºF(12ºC). If the spa was recently filled with cold
water then no action is required at this time. The system will automatically turn on the heater. The
heater will still work even in the economy mode (ECO Mode) The spa will automatically bring the
water temperature up to a safe temperature then shut down. When the water temperature in the
spa is equal to or less than 50ºF(10ºC) the spa will turn on the high speed pump for 5 minutes,
the heater is not active. Then the system will automatically start the heater and the low speed
pump for 20 minutes. These cycles will be repeated until the spa reaches a safe temperature.
The topside control will display “FC” - current water temperature - “FC”. This must be repaired
by a service technician if the problem persists.
“Ht” High temperature condition.
The control system checks the spa water for a temperature equal to or above 110ºF(43ºC). If the
water temperature is equal to or above 110ºF(43ºC), The topside control will display the code
“Ht” - current water Temp - “Ht”. All the Jets will shut down. This issue can be caused by
outside air temperatures being too high in the summer time. Also excessive circulation cycle
times in the summer can cause this error: i.e. resetting the high speed Jets continuously after
each 20 minute shut down cycle. This must be repaired by a service technician if the problem
persists.
“OHt” Overheating Condition / Watchdog.
The system checks the spa water for temperature equal to or above 120ºF(48ºC) or the heater
enclosure temperature that is equal to or above 125ºF(51ºC). If the spa water temperature is
equal to or above 120ºF(4C) or the heater enclosure temperature is equal to or above
125ºF(51ºC), the topside control will flash “OHt” - current Water Temp - “OHt”. The “OHt”
condition requires a manual reset either by pushing the buttons simultaneously, or by
turning the main power off and then back on. The heater hi-limit switch cannot reset until the
heater enclosure temperature drops below 123ºF(50ºC) or the water temperature in the spa
drops below 117ºF(47ºC). This must be repaired by a service technician if the problem persists.
Note: For manual reset, push the buttons simultaneously or turn the main power off
and then back on.