Error Messages
The control system is a self-diagnostic system. The system will automatically display the error
messages in the topside control window, if a problem is detected.
HtS High Temp Sensor:
The control system checks the heating components and temperature sensor for errors. If a tem-
perature sensor is open or an error is detected, the topside control will display the code HtS -
current water temp - HtS. The heater and the high/low speed jet will shut down. The automatic
reset will occur after the open sensor condition is fixed. If the temperature sensor is closed and
an error is detected, the topside control will display the code HtS - OHt - current water temp -
HtS. The entire system will be disabled and the spa will need to be manually reset after the
shorted sensor condition is fixed. This must be repaired by a service technician if the problem
persists.
tS Temp Sensor:
The control system checks the water temperature sensor for errors. If a temperature sensor is
open and an error is detected, the topside control will display the code tS - 0 - tS. The heater and
the High/low speed jet will shut down. The automatic reset will occur after the open sensor
condition is fixed. If the temperature sensor is closed and an error is detected, the topside control
will display the code tS - 255 - Ht - OHt - tS. The entire system will be disabled and a manual
reset will be required after the shorted condition is fixed. This must be repaired by a service
technician if the problem persists.
PS1:
The control system checks for a closed pressure switch with the low speed pump or high speed
pump active. If an error is detected, the topside control will display PS1 - current water temp -
PS1. The heater will be deactivated. An automatic reset will occur if this condition is fixed within
2 1/2 minutes. After 2 1/2 minutes the jet pump will shut down. The manual reset is required if this
condition has existed more than 2 1/2 minutes. This error may be caused by a dirty filter. Remove
and clean the filters before calling for service. For manual reset, push the buttons simulta-
neously or turn the main power off and then back on. This must be repaired by a service techni-
cian if the problem persist.
PS2:
The system checks for an open pressure switch when the pump is off. If an error is detected, the
topside control will display the code PS2 - current water temp - PS2. The heater will shut down.
An automatic reset will occur if this condition is fixed. The pressure switch may be out of adjust-
ment or the water level is too high. This must be repaired by a service technician if the problem
persists.
dCP DC power:
The system checks for DC power at the relay (master control relay). Code dCP is displayed if an
error is found. This message can appear after a power interruption or lightning. This must be
repaired by a service technician if the problem persist.