Troubleshooting guide
5
Branch
AWG (mm
2
) Wire Gauge Size at 90° C
Voltage/ Full Circuit Dist in Ft. (M) - Service to Motor
Model Hertz Load Breaker 0-100 101-200 201-300
No. (1 Phase) Amps Amp Rating (0-30) (31-60) (61-90)
Single Speed Pumps:
5DJAFB-0001, -0101 230/50 5.6 15 14 (2) 14 (2) 12 (3)
5DJAEB-0001, -0101 230 / 50 5.5 15 14 (2) 10 (5.5) 8 (8.4)
5DJAGB-0003, -0103 230 / 50 8.7 15 14 (2) 14 (2) 12 (3)
DJAEA-0001 115 / 60 12 15 14 (2) 10 (5.5) 8 (8.4)
DJAEA-0007 115 / 60 12 15 14 (2) 10 (5.5) 8 (8.4)
DJAAGB-0001 230 / 60 11.1 15 14 (2) 14 (2) 12 (3)
DJAAGB-0005 230 / 60 12.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAAGB-0007 230 / 60 12 15 14 (2) 10 (5.5) 8 (8.4)
DJAAGB-0051, -0151 230 / 60 11.1 15 14 (2) 14 (2) 12 (3)
DJAAGB-0091 230 / 60 11.1 15 14 (2) 14 (2) 12 (3)
DJAEB-0001 230 / 60 6.2 / 1.7 15 14 (2) 14 (2) 14 (2)
DJAGB-0001 230 / 60 10.6 15 14 (2) 14 (2) 12 (3)
DJAGB-0021H, -0121H 230 / 60 10.6 15 14 (2) 14 (2) 12 (3)
DJAGB-0073, -0173, -3073, -3173 230 / 60 8.6 15 14 (2) 14 (2) 12 (3)
DJAGB-3173 230 / 60 8.6 15 14 (2) 14 (2) 12 (3)
DJAGB-0091, -0191 230 / 60 10.6 15 14 (2) 14 (2) 12 (3)
DJAGB-9051M 230 / 60 10.6 15 14 (2) 14 (2) 12 (3)
DJAGB-9055M, -9155M 230 / 60 9 15 14 (2) 14 (2) 12 (3)
DJAGB-9071M 230 / 60 10.6 15 14 (2) 14 (2) 12 (3)
DJAGB-9073, -9173 230 / 60 8.6 15 14 (2) 14 (2) 12 (3)
DJAHB-0007 230 / 60 12 15 14 (2) 14 (2) 12 (3)
DJAHB-0021H, -0121H 230 / 60 12 / 3.7 15 14 (2) 14 (2) 12 (3)
DJAHB-0041, -0141, -3141 230 / 60 12 15 14 (2) 14 (2) 12 (3)
DJAHB-0151 230 / 60 12 15 14 (2) 14 (2) 12 (3)
DJAHB-0055M, -0155M 230 / 60 12 15 14 (2) 14 (2) 12 (3)
DJAHB-0097 230 / 60 12 15 14 (2) 14 (2) 12 (3)
DJAFA-0001 115/60 16 25 12 (3) 8 (4) 6 (14)
DJAFC-0002 115/230 /60 16.4 / 8.2 25 / 15 12 (3) 8 (4) 6 (14)
DJAFC-0051M, -0151M 115/230 /60 16.4 / 8.2 25 / 15 12 (3) 8 (4) 6 (14)
DJAFC-0052, -0072, -0172 115/230 /60 16.4 / 8.2 25 / 15 12 (3) 8 (4) 6 (14)
DJAFC-0097 115/230 /60 16 / 8 25 / 15 12 (3) 8 (4) 6 (14)
DJAFC-3103D 115/230 /60 16.4 / 8.2 25 / 15 12 (3) 8 (4) 6 (14)
DJAGC-0007 115/230 /60 20 / 10 25 /15 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3)
Two-Speed Pumps:
5DJAYEB-0001, -0101 230/50 5.7 / 1.6 15 14 (2) 14 (2) 14 (2)
5DJAYFB-0097, 3007, -3097 230/50 8.2 / 2.6 15 14 (2) 14 (2) 12 (3)
DJAYEA-0001, -0002 115 /60 13 / 3.7 20 12 (3) 10 (5.5) 8 (8.4)
DJAYEA-0007 115 /60 11 / 2.9 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0052, -0152 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0061 115 /60 12 / 3.3 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0062, -0162, -3062 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0062A, -0162A 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0082, -0182 115 /60 11 / 2.9 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0112 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-0142A 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3022 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3052, -3152 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3052M, -3152M 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3097, -3197 115 /60 11 / 2.9 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3113 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-3142B 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYEA-9103 115 /60 10.4 / 3.6 15 14 (2) 10 (5.5) 8 (8.4)
DJAYFA-0001 115 /60 13 / 3.7 20 12 (3) 10 (5.5) 8 (8.4)
DJAYFA-0007 115 /60 13.8 / 3.8 20 12 (3) 10 (5.5) 8 (8.4)
TABLE IA – RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA
NOTE: The second character of the model number suffix (the four characters following the dash) on pumps packed in bulk will be a “1”
(for example, – 3115). Identical pumps packed individually will have a suffix with a “0” replacing the “1” (for example – 3015).
When replacing a pump having a suffix “-X1XX”, order the same model with suffix “-X0XX”. When replacing a pump having a suffix “-X0XX”,
do not change the suffix.