Ozone
The ozone generator runs during normal circ pump operation. Your system is
configured with the ozone disable feature, the ozone generator will turn off for 1
hour any time a function button (Jets 1, Jets 2, Jets 3, etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 44˚F (approximately 6.7˚C) within
the heater, then the pump automatically activates to provide freeze protection.
The equipment stays on until 4 minutes after the sensors detect that the spa
temperature has risen to 45˚F (approximately 7.2˚C) or higher.
Locking the Panel (PL - see page 36 under Indicator Light)
Press "Time" "Jets 1" then "Warm" within 3 seconds. When locked, the PL indi-
cator light will light. All buttons are frozen except the "Time" button. To unlock
the panel, press "Time" "Jets 1" then "Cool" within 3 seconds.
Locking the Set Temperature (TL - see page 36 under Indicator Light)
Press "Warm" or "Cool" then "Time", "Jets 1", and "Warm" within 3 seconds to
activate the lock. The TL indicator light will light when the set temperature is
locked.
To unlock the set temperature, press "Warm" or "Cool" then "Time", "Jets 1"
and "Cool" within 3 seconds.