DOWN EAST (2 -3 PUMP SYSTEMS)
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is energized.The second filter
cycle begins 12 hours later. Filter duration is programmable for 2,4, 6, 8 hours
or for continuous filtration (indicated by “FI LC”).The default filter time is 2
hours.
To program, press “Warm” or “Cool”, then “Jets.” Press “Warm” or “Cool” to
adjust.Press “Jets”to exit programming.
The low speed of the pump runs during filtration and the ozone generator
(if installed) will be enabled.
Freeze Protection
If the temperature sensors detect a drop to below 44˚F /6.7˚C within the heater,
the pump automatically activates to provide freeze protection. The equipment
stays on until 4 minutes after the sensors detect that the spa temperature has risen
to 45˚F /7.2˚C or higher. In colder climates,an optional additional freeze sensor
may be added to protect against
freeze conditions that may not be sensed by the
standard sensors.Aux freeze senso
r protection acts similarly except with the
temperature thresholds determined by the switch and without a 4-minute delay in
turnoff. See your dealer for details.