User guide
Page 5 55862_97_A
B
a
lbo
a
J94
J
95
TB
1
J9
3
J
96
K9
K10
K
5
K13
J
2
5
K15
K1
J
82
J
1
5
J
22
J
24
RLY
AUX
. F
S
EN.
A
VA
C
S
EN. B
J
83
C
FG
J
17
T
S
T
J
91
S
WIT
C
HBANK
A
S
WIT
C
HBANK B
J
19
UV
J
18
TV1
J
5
1
J21
TV
2
F1
G
N
G
N
G
N
G
N
G
N
G
N
G
N
J
14
J
16
G
N
F7
F6
F
7, T30
A
480
V
F
6, T30A 480V
F9
F
9
,
T30A 480V
K4
K
2
K3
K11
J
1
J
12
J
11
J5
BALB
O
A IN
S
TRUMENT
S
, IN
C
.
GL8000 Mach
3
CO
PYRI
G
HT 2006
P/N 22960
_
C
MADE IN
U
.
S
.A.
K6
K8
K7
J
2
7
J7
9
J
5
9
J
23
J
2
8
J26
J26
J
32
J
1
3
J
30
J5
7
J
5
8
J90
J90
HTR
2
H
TR1
J
5
4
J
5
3
G
N
G
N
J
3
9
1
2
3
J
3
J2
J4
J
56
J5
5
J
6
0
J
75
J7
6
J6
2
J
1
4
J
74
F
5, F10
A
250
V
F5
F
4
3
2
1
3
2
1
3
2
1
3
2
1
F
4, F3A 250V
J
33
J
4
1
J
8
1
J
45
J
29
J
5
0
J3
7
J10
J
3
8
3
2
1
3
2
1
3
2
1
M
1
M11
3
2
1
J
5
2
J
7
G
N
J
8
J
4
7
J
49
1
2
3
4
J
4
6
BARCODE
W1
N
G
J
8
4
W
2
J
3
6
E
XT I
/O
M
AIN PANEL
S
AU
X PANEL
S
J
7
2
J
73
J
7
1
J
70
J
1
6
J
4
0
J
34
J
31
AD
CM
REM
O
TE
J
69
J
20
F2
F2, T 0.5
A
250
V
J
77
J
9
J6
10 VA
C
-
A
1
0 VA
C
-B
Configuration
Settings
Enabled
RTC
Enabled
3.0 kW
Spa
Light
A. V.
Ozone
Circ Pump
PS-34
2-Spd P2
2-Spd P1
Pump 4 Pump 3
To J12
PS-34
PN 25093
White
Red
White
Green
Black
Green
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 6#IRC0UMP
s 63PA,IGHT
s 6/ZONE
s 6!<6(Stereo)
s 6K7(EATER
s -0-AIN0ANEL
Switchbank A Switchbank B
B2, Assignable
B3, Assignable
B4, Assignable
B5, Assignable
B6, Assignable
A5, Assignable
A6, Assignable
B1, Assignable
B8, Assignable
B9, Assignable
B10, Assignable
B11, Assignable
B12, Assignable
B7, Assignable
A8, Assignable
A9, Assignable
A7, Assignable
A11, Special Amp Rule OFF
A12, Memory ON
100
139
30
SSID #
J91
J91
J83
Config Settings
Enabled
RTC
Enabled
B2, Not Assigned
B3, Not Assigned
B4, Not Assigned
B5, Not Assigned
B6, Not Assigned
A5, Not Assigned
A6, Not Assigned
B1, Not Assigned
B8, Not Assigned
B9, Not Assigned
B10, Not Assigned
B11, Not Assigned
B12, Not Assigned
B7, Not Assigned
A8, Not Assigned
A9, Not Assigned
A7, Not Assigned
A3, + 2 Pumps w/Heat
Neutral (Common) AC Connections
Special AC Connections
Line AC Connections
10 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
HIPot Testing Note:
Disconnect slip terminal with green
wires from J90 prior to performing
HiPot test. Failure to disconnect will
cause a false failure of the test.
Reconnect terminal to J90 after
successful completion of HiPot test.