Specifications
4
POWER REQUIRMENTS
An illustration showing the proper electrical connections for 240 volt service has been provided for
you. (Figure 2) Be sure to follow these and all other instructions carefully. Be sure that all
connections are tight before switching on the circuit breaker.
CAUTION! Failure to abide by specification listed may result in damage to equipment and may void
the warranty. IF THE SPA IS WIRED INCORRECTLY, YOUR WARRANTY WILL BE VOID ON
ANY BURNED OUT ELECTRICAL EQUIPMENT.
G.F.C.I (Ground Fault Circuit Interrupter)
IMPORTANT
This service must be single phase. High voltage can seriously injure or kill. Always use a certified
electrician when connecting new spa.
The National Electrical Code states that a service disconnect breaker box (a G.F.C.I. can be used
for this purpose) must be located at least 5 feet away from the spa and should be conveniently
located near the equipment bay. If it is not in plain sight, keep the disconnect padlocked when in the
off position.
Remember, high voltage is still accessible in the housebreaker box even though you have turned off
the spa breaker.
G.F.C.I HOOK - UP
Figure 2
G.F.C.I
CONDUIT
HS2000VS
See Page 5
Figure 4
NEUTRAL/GROUND
BAR
INPUTS FROM
TRANSFORMER