Specifications

13
OPERATING INSTRUCTIONS
Filtration Pump
Your system equipped with the filtration pump. The filtration pump provides 24 hour continuous water circulation and
filtration. The filtration pump turns over the entire spa water capacity at a minimum of 3 times every hour. It works like this:
a dedicated, energy efficient filtration pump constantly draws water from the spa through the filter and the heater (heating
only when necessary), then back to the spa. The ozone output is on whenever the filtration pump is running except when the
jet pump or blower is activated by the user. The ozone generator will turn off for one (1) hour any time a function button (Jets
1, Jets 2 or Blower.) is pressed. The filtration pump will turn off for 30 minutes at a time when the water temperature
reaches 3°F (1.5°C) above the set temperature (most likely this will happen in a very hot climate or during summer).
Heater
Your spa is equipped with an electrical heater. By setting your thermostat to the desired temperature, your heater will
automatically turn on and off as needed. The temperature set point (set temperature) can be adjusted from 80°F to
104°F/26°C-40°C. To raise the set temperature press the “Warm” button. To lower the set temperature, press the “Cool”
button. The start up temperature is set at 100°F/37.5°C. The last measured temperature is constantly displayed on the LCD
display.
In Economy mode the heater heats the spa water only during filter cycles.
In sleep mode the heater heats the spa water to within 20°F (11°C) of set temperature only during filter cycles.
Present Filter Cycles (For use during economy mode)
The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later. Filter duration
is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by “FILC ”). The default filter time is 2 hours. To
program, press “Warm” or “Cool”, then “Jets 1”. Press “Warm” or “Cool” to adjust. Press “Jets 1” to exit programming. At the
beginning of each filter cycle the blower purges for 30 seconds; the pumps purge for 5 minutes. The only effect filter duration
has is: 1) During the filter, the circ pump never turns off, and 2) In Economy and Sleep Modes, heating only occurs during
the filter cycle.
Ozone water maintenance system
Your spa is equipped with ozone purification system. You will find that your spa water stays fresh and clear with significantly
less chemical sanitizer usage. You will be able to go longer between complete spa draining. The ozone generator operates
in conjunction with the filtration pump. Ozone generator is on any time the filtration pump is running. Ozone generator will
turn off for one (1) hour any time a function button (Jets 1, Jets 2, Blower.) is pressed.
Freeze Protection
If the temperature sensor detects a temperature drop to 44°F (6.7
°C) within the heater, then the pump automatically
activates to provide freeze protection. The equipment stays on until four (4) minutes after the sensors detect that the spa
water temperature has risen to 45°F(7.2°C) or higher.