Specifications

11
Your spa is equipped with a Topside control panel, air control knobs, on-off waterfall valve, aromatherapy canister and
diverter valve. All controls are located on the top rail of the spa. These controls let you operate many of the special features
on your spa. The main control panel controls all of the spa functions. The heater indicator LED light and LCD display will aid
in determining the status of the spa. By familiarizing yourself with following information, you will be able to gain the full
benefit afforded by the various functions of your spa.
Turn on power to hot tub at the home circuit breaker. The GFCI circuit breaker must be tested before each use of
the spa. Press the "Test" button on the breaker and the circuit breaker should go to the tripped position. Reset the
GFCI and ensure it stays on. The Display goes through specific sequences. At first the Display will show a series of
four numbers. The first three numbers in combination are called the software ID. Following the software ID will be
either 12 or 24, indicating the heater wattage the software is configured for. After any power-up, the spa first goes
into priming mode indicated by "Pr". During this mode heating is disabled. All pumps can be turned on to any
available speeds (as needed for priming) from the front panel. To exit Priming mode and begin normal spa
operation, press any set temperature button Up/Down). The filtration pump will automatically activate. The filtration
pump is turned on and doesn't turn off unless detected temperature gets 3 degrees above set temperature As soon
as "Pr" is indicated on the top side panel, push Jets 1, Jets 2 buttons to start the pumps. Push buttons until both
pumps are on high speed. If the pumps have not primed after two minutes, and water is not flowing from jets in the
spa, do not allow the pumps to continue to run. Turn the power off at main panel and vent air from the pumps. Do
this loosening the union nuts on the discharge side of pumps. Turn the power back on at main panel. This will
initiate a new pump priming mode. Sometimes momentarily turning pump off and on will help to prime. Do not do
this more than five times. Check and adjust, if necessary, the water and air flow of every jet. See Air Volume control
and Adjusting Jets sections for details. Priming mode will time out after 4 minutes. The filtration pump and ozone
generator will automatically turn on. After 6 minutes the actual water temperature will be displayed and heater will
turn on if heat is required. The blower purges all air lines for 30 seconds and pump 1 (low) and pump 2 (high) purge
all water lines for 5 minutes.
Setting temperature to desired heat: To adjust your spa water temperature press the WARM or COOL button pad.
Default setting is 100F. The set temperature advances or decreases by one degree each time one of these buttons
is pressed. The heater will turn off when the temperature corresponding to the thermostat setting is achieved. The
heater will reactivate after the water cools to approximately 1F below the set temperature. Setting the thermostat at
maximum position will not accelerate the heating process. This will only result in a higher ultimate temperature. Heat
icon light is on when the heater is activated.
Add Start-Up Chemical as recommended by your dealer. Refer to Page18 for general guidance.
Place Spa Cover On Hot Tub
Keeping the insulating cover in place anytime the hot tub is not in use will reduce the time for heating, thereby
minimizing operating costs.
The time required for initial heat-up will vary depending on the starting water temperature and ambient condition.
START-UP INSTRUCTIONS
Mode
Cool
Warm
Light
Blowe
r
Jets 2
Jets 1
Heater Indicator Li
g
ht
LCD Dis
p
la
y