Diagnostic Display Messages on Main Control Panel
SMART WINTER MODE / FLASHING ABOVE FILTER ICON
This system prevents the water from freezing in the plumbing or the pumps. An onboard
sensor continuously checks the ambient air temperature in the control pack. If at any time
the temperature falls from a range of 43ºF the Smart Winter Mode will be activated for the
next 24 hours, even if the temperature returns to above 43ºF. During this Smart Winter
Mode the range of temperature will determine the frequency of the pumps operation. The
colder the ambient temperature, the more frequently the pumps will run. The time range will
vary from every 15 minutes to every 2 hours. When the pumps are operating because of this
feature, the filter cycle icon on the display will flash. No corrective action is necessary.
SUMMER SETTING MODE / ”SSET”
Your spa is equipped with this feature to prevent heat build up.
Standard (Outdoor) Mode: When water temperature is 2ºF greater than set temperature, the
circulation pump and ozone generator will turn off for 3 hours. After 3 hours the circulation
pump and ozone generator will turn on again for 1 hour and pump 1 will run for 1 hour then
turn off again for 3 hours; this cycle will keep repeating. When the circulation pump and
ozone generator are off “SSEt” and the water temperature are alternately displayed on the
panel (SSEt = summer setting). The circulation pump turns on automatically if the water
temperature drops below 1ºF of the set temperature.
Operations Trouble Shooting Guide Cont...
Problem Probable Cause Solutions
Spa jets/pump(s) • Normal power filtration cycle • No action necessary
turn on • Summer Setting mode cycle activated • No action necessary
automatically • Smart Winter mode cycle activated • No action necessary
Not able to • Panel may be locked • Hold down blower key until
operate main “Uloc” appears on the digital display
control panel • Panel may have malfunctioned • Contact your dealer
Water does • Bad water chemistry • Balance water
not clear up • Dirty filter cartridges • Clean or replace filters
• Ozone generator not operating or • Locate ozone generator, look for
ozone chip needs replacement ultraviolet light to be illuminated
through window on ozone generator
• Bromine/chlorine residual levels Adjust Bromine/chlorine levels.
too low Shock if necessary. May have to
replace water