HL  A significant difference  Check water level in spa. Refill if 
temperature sensors  necessary. If the water level is okay, make   
    has been detected.  sure the pumps have been primed. If  
    this could indicate a   problem persists, contact your dealer or 
    flow problem.  service organization. 
  LF  Persistent low flow  Follow action required for “HL” message. 
    problems. (Display on the  Turn spa off, then back to restore heating 
    fifth occurrence of “HL”  capability. 
    message.) Heater is shut 
    down, but other spa functions 
    continue to run normally. 
  dr  Possible inadequate water,  Check for dirty filers. Check water level in 
    poor flow, or air bubbles  spa. Refill if necessary. If water level is 
    in the heater. Spa is shut  okay, make sure the pumps have been 
    down for 15 minutes.  primed. Press any button to reset, or this 
message will automatically reset within 15 
minutes. 
      If problem persists, contact your 
      dealer or service organization. 
  dy  Inadequate water detected  Follow action required for “dr” message. 
    in heater. (Displays on  Spa will not automatically reset. 
    third occurrence or   Press any button to reset. 
    “dr” message)   
    Spa is shut down.   