Operation
Activating the MultiRanger
All the instructions in the following procedures apply to the hand programmer and
assume that the MultiRanger is activated.
1. Power the MultiRanger.
2. Point the programmer at the unit and press PROGRAM .
3. Press DISPLAY .
Changing Parameters
1. Starting in RUN mode, press PROGRAM and then press DISPLAY to put the
unit into PROGRAM mode.
2. Press DISPLAY to select the Parameter Number field.
3. Enter the Parameter Number (e.g. 110). After the third digit is entered, the parameter
value is shown.
4. Enter the new value, and press ENTER . The MultiRanger interprets the value,
either accepting or replacing it with a valid value.
Helpful Hints
For parameters P001 to P009, press a single digit (1–9) and then press DISPLAY
to show that parameter.
The ? icon indicates that the MultiRanger has accepted the value but that it conflicts
with other values entered. Double-check your programming.
By default, the SCROLL arrows show only the Quick Start parameters and
any that have been changed.
P733 sets all parameters to be scroll-accessed.
Note: Power up display
Single Point Model
preset to display distance from the face of the transducer to the
material
transducer selection is preset for the XPS-10
empty distance is preset to 5m
•Dual Point Model
starts in an OFF state and does not take level measurements
to set up measurement, the quick start parameters must be
configured
See Quick Start parameters on page 119
Note: If Parameter Value alteration is not permitted, access the Lock parameter
(P000) and enter the security code, (see Security below).