Instruction manual
7ML19981FB06 MultiRanger 100/200 – INSTRUCTION MANUAL Page 213
mmmmm
Parameters
P842 Short Shot Frequency
Adjust the short shot transmit pulse frequency (in kHz).
This feature is automatically altered when Transducer (P004) is altered.
P843 Long Shot Frequency
Adjust the long shot transmit pulse frequency (in kHz).
This feature is automatically altered when Transducer (P004) is altered.
P844 Short Shot Width
Adjust the width (in ms) of the short shot transmit pulse.
This feature is automatically altered when Transducer (P004) is altered.
Primary Index
Single Point Model Dual Point Model
Global Transducer
Values Range: 41 to 46 kHz, nearest acceptable value is returned
Altered By •P004 Transducer
Related
• P840 Short Shot Number
• P844 Short Shot Width
• P850 Short Shot Bias
• P851 Short Shot Floor
• P852 Short Shot Range
Primary Index
Single Point Model Dual Point Model
Global Transducer
Values Range: 41 to 46 kHz, nearest acceptable value is returned
Altered By • P004 Transducer
Related
• P841 Long Shot Number
• P842 Short Shot Frequency
• P843 Long Shot Frequency
• P845 Long Shot Width
Primary Index
Single Point Model Dual Point Model
Global Transducer
Values Range: 0.000 to 5.000
Altered By • P004 Transducer
Related
• P840 Short Shot Number
• P842 Short Shot Frequency
• P845 Long Shot Width
• P850 Short Shot Bias
• P851 Short Shot Floor
• P852 Short Shot Range