System information
SECURITY DOOR CONTROLS
3580 Willow Lane
•
Westlake Village, CA 91361
Email: Service@sdcsecurity.com
•
www.sdcsecurity.com
Price List Effective January 1, 2006
37
PTH
See details page 14
602RF
101-4AM
SPECIFY D.E. OPERATION GKK LIST
ND UBC, California Building Code, NFPA 101, NFPA 1/UFC, SBC, IBC, IFC Compliant
15 sec. xed exit delay, adj. 0, 1, 2, 3, sec. nuisance delay
UBC and California (OSHPD) compliant manual power up feature
N/C
NH NFPA 101, NFPA 1 - UFC, SBC, IBC, IFC Compliant
30 sec. xed exit delay, adj. 0, 1, 2, 3, sec. nuisance delay
N/C
BD BOCA National Building Code Compliant
15 sec. xed exit delay, 1 sec. nuisance delay, auto reset 30 sec. after door closure
N/C
BH BOCA National Building Code Compliant
30 sec. xed exit delay, 1 sec. nuisance delay, auto reset 30 sec. after door closure
N/C
Access Control
E Electric Device Lock/Unlock. Exterior access control capability locks and unlocks outside
trim, failsecure standard, eld reversible for failsafe operation.
Input: 200 mA @ 24VDC
Output: SPDT 2 Amp @ 30VDC locked/unlocked status standard with E option
418.00
Monitoring
L Latchbolt status output, SPDT, 1.5 Amp @ 30VDC POA
Power Supply Capacity
Door sequencing is not required Less E Option With E Option
602RF 1 Amp 12/24VDC Class 2 power supply 2 max 1 max 200.00
632RF 2 Amp 12/24VDC Class 2 power supply 4 max 2 max 390.00
See page 42 for battery backup, options and door control modules
SPECIFY POWER TRANSFER DEVICE List
PT-3 Stainless steel armored power transfer loop with aluminum termination box
(Special nish not available)
36.00
PTH-4Q 4 wire power transfer hinge: 1-pair 1 Amp; 1-pair 250 mA
(specify nish below)
UL10B Listed for use with up to 3 hour re rated doors
150.00
PTH-10Q
10 wire power transfer hinge: 1-pair 1 Amp; 4-pair 250 mA (specify nish below)
UL10B Listed for use with up to 3 hour re rated doors
Required for applications with remote status outputs or remote control inputs
195.00
REMOTE KEYPAD AND ANNUNCIATION List
928 EntryCheck digital keypad. Provides keyless reset, manual power up and bypass. 140.00
101-1A One Station remote annunciator
96.00
101-4AM Four station remote annunciator 310.00
See page 54 for more details about remote desk top control consoles
See page 38 for more details about remote wall mount annunciators
SPECIFY ELECTRIC OPTIONS Add to List
SPECIFY POWER SUPPLY FOR UL COMPLIANCE List
PT-3
KEY CYLINDERS List
Two key cylinders may be required for each exit device. Key cylinders may be provided by SDC or by others.
All Exit Devices require at least one (1-1/8") Mortise Key Cylinder for electronic operation of alarm reset,
momentary bypass and sustained bypass.
A second key cylinder is required with Dummy and Active Trim Functions 2 and 3 for exterior mechanical key operation
Exit Only Function 0 does not require a mechanical key cylinder on the exterior
•
•
•
CYL-6PKD 6 pin mortise cylinder, 2 keys, keyed different, 1-1/8". For mortise device 30.00
RIM-6PKD 6 pin rim cylinder, 2 keys, keyed different. For rim and vertical rod devices 30.00
Keyed Alike POA