System information

1511S / T VOICE & DIGITAL ANNUNCIATION FIELD SELECTABLE ACTUATION 1650 lbs Holding Force Standard
830/450 mA @ 12/24VDC (single)
1200 lbs Energy Saver Option E
380/225 mA @ 12/24VDC (single)
Control more locks with fewer power supplies
Save on electricity consumption and power
supply investment
The Exit Check® 1511S series incorporates an
alternating 85 db tone and voice message
with a digital countdown display and sign
that provides clear and comprehensive instruc-
tions for persons without prior knowledge of
door operation. This is especially significant for
those who are
blind or hearing impaired.
• Door Movement
• Exit Sense Bar
• Exit Device Switch Kit (See page 51)
• Latch Monitoring Strike (See page 51)
SINGLE MODEL TANDEM MODEL DOUBLE MODEL POA Consult Factory
For use with single doors equipped with Exit
Sense Bars, surface vertical rod, concealed
vertical rod, mortise and rim mount exit devic
-
es, mortise locksets and cylindrical locksets.
For use with pairs of doors equipped with Exit
Sense Bars, surface mounted vertical rod exit
devices and concealed vertical rod exit devic-
es with surface mounted triggers and strikes.
Activating either door unlocks both doors.
For use with pairs of doors equipped
with Exit Sense Bars, mortise, rim and con
-
cealed vertical rod exit device with concealed
strikes and triggers, mortise locksets and
cylindrical locksets. Activating either door
unlocks both doors.
ELECTRICAL SPECIFICATIONS
Input Voltage: Auto Voltage Sensing
12/24VDC ± 10%
Standard 1650 lbs holding force
1511S 830/450 mA @ 12/24VDC
1511T 1500/850 mA @ 12/24VDC
Energy Saver E Option 1200 lbs
Holding Force
1511S 400/275 mA @ 12/24VDC
1511T 650/400 mA @ 12/24VDC
CONTROL INPUTS
Request to Exit: Normally open, dry
Fire Alarm Release: Alarm panel closed dry
contact. Opening of contact releases lock.
MONITORING OUTPUTS
Alarm Output:
SPDT Dry, 1 Amp @ 30VDC
Lock Secure / Unlocked Output:
SPDT Dry, 1 Amp @ 30VDC
DPS Door Position Status: (option)
SPDT Dry, 250 mA @ 30VDC
BAS Magnetic Bond Status: (option)
SPDT Dry, 250 mA @ 30VDC
ATS Anti Tamper Sensor: (option)
SPDT Dry, 1 Amp @ 30VDC
DIMENSIONS
Single: 11” L x 2
3
/
4
” H x 2
5
/
8
” D
(279 L x 70 H x 67 D mm)
Tandem: Master: 11” L x 2
3
/
4
” H x 2
5
/
8
” D
(279 L x 70 H x 67 D)
Slave: 11” L x 2
3
/
4
” H x 2
5
/
8
” D
(279 L x 70 H x x 67 D mm)
Armature: 7
3
/
8
” L x 2
3
/
8
” H x
9
/
16
” D
(187 L x 60 H x 14 D mm)
Sign: 13” L x 4
1
/
2
” H
(330 L x 114 H mm)
1511S
*Office of Statewide Health Planning & Development (California)
EXIT CHECK
®
DELAYED EGRESS LOCK GKK
1511T
1512D
STANDARD DELAYED EGRESS MODEL NUMBERS
UBC, SBC, IBC, IFC, NFPA 101,
NFPA 1-UFC, California Building Code/OSHPD* Compliant
BOCA Compliant
Chicago Compliant
1511S ND K V
Single
1511T ND K V Tandem
1511S BD K V Single
1511T BD K V Tandem
1511S CD K V Single
1511T CD K V Tandem
NEW
NEW
Voice & Digital Display Standard
Energy Saver Optional
SECURITY DOOR CONTROLS
3580 Willow Lane
Westlake Village, CA 91361
Email: Service@sdcsecurity.com
www.sdcsecurity.com
Price List Effective January 1, 2006