917 INDOOR EntryCheck
JK LIST
ELECTRICAL SPECIFICATIONS
Voltage: 12/24 VAC/DC
Current: 20 mA @ rest, 120 mA maximum
Outputs: Relay 1 - SPDT, 6 Amps @ 30VDC.
Outputs 1,2,3,4 - Switch to common, 500mA @ 12VDC
OPTIONS Add to List
925 OUTDOOR EntryCheck
JK LIST
ELECTRICAL SPECIFICATIONS
Voltage: 12/24 VAC/DC
Current: 10 mA typical, 150 mA maximum
Outputs: Relay 1 - Form “C”, 5 Amps @ 24VDC
Relay 2 - Form "C", 1 Amp @ 24 VDC
Outputs 3 and 4 - Switch to common, 100mA @ 30VDC
Operating Temperature: -20 degrees to +130 degrees F
Operating Humidity: 5% to 95% non-condensing
Housing: 4"W x 5.5"H x 3"D
928 EntryCheck
JK LIST
ELECTRICAL SPECIFICATIONS
Voltage: 12/24 VAC/DC
Current: 10 mA typical, 150 mA maximum
Outputs: Relay 1 - Form “C”, 5 Amps @ 24VDC
Relay 2 - Form "C", 1 Amp @ 24 VDC
Outputs 3 and 4 - Switch to common, 100mA @ 30VDC
Operating Temperature: -20 degrees to +130 degrees F
Operating Humidity: 5% to 95% non-condensing
Housing: 3"W x 5"H x 3"D
U 630 Stainless Steel (standard)
N/C H 613 Oil Rubbed Bronze 40.00
C 605 Bright Brass 40.00 P 625 Bright Chrome 40.00
D 606 Dull brass
40.00
TR12 Plug in power supply
(optional)
120 VAC primary, secondary screw terminals with ground terminal
Output 1: Fused unregulated 12VDC @ 780mA
Output 2: Regulated 12VDC @ 150mA
68.00
917U 120 user codes, 1 to 6 digits in length, programmable for individual or simultaneous control
of 1 relay output and 4 voltage outputs momentary, timed or latching. Automatic time-out,
REX input, duress alarm, forced entry alarm, 3 LEDs.
140.00
925 Outdoor keypad with 480, 1-6 digit user codes for activation of 2 relay outputs program-
mable to activate separately or simultaneously for timed or latching applications. Two solid
state outputs are programmable to signal two of the following: forced entry, door ajar,
keypad lockout, alarm shunt, request-to-exit, relay 1 disable or keypad active. Additional
features include timed anti-passback and two LEDs.
330.00
928 Keypad with 480, 1-6 digit user codes for activation of 2 relay outputs programmable to
activate separately or simultaneously for timed or latching applications. Two solid state
outputs are programmable to signal two of the following: forced entry, door ajar, keypad
lockout, alarm shunt, request-to-exit, relay 1 disable or keypad active. Additional features
include timed anti-passback and two LEDs.