System information
SECURITY DOOR CONTROLS
3580 Willow Lane
•
Westlake Village, CA 91361
Email: Service@sdcsecurity.com
•
www.sdcsecurity.com
Price List Effective January 1, 2006
4
APPLICATIONS
Laboratories, clean rooms, money counting rooms, restricted dark rooms, computer rooms and more.
OPERATION
Both doors are normally closed and locked. Unlocking either door
causes the other to be incapable of being unlocked. A key switch
(D) is provided for system activation and deactivation. Doors are
accessed by Digital Keypad (C).
SYSTEM COMPONENTS SHOWN
(A) 631RFA-UR2-MAN-B
(B) 1511-DPS-BAS or 1511-BAS
(C) 917 Digital Entry Momentary Access
(D) 701 Key Switch ON-OFF
ALTERNATE “B” COMPONENTS/LOCKING DEVICE
Refer to literature for lock specifications.
EmLocks Electric Strikes HiTower Bolt Locks
1565-BAS-DPS 51-A-LCM-LBM 7530-S FS23M-69
1511-BA-DPS-TJ 52-B-LCM-LBM 7560-S 1190A-69
7830-DS
Indicates Fail Secure
ALTERNATE “C” COMPONENTS/ACCESS CONTROL - Refer to literature for switch specifications.
Key Switch Desk Switch Keypad Card & Keypad Reader
702 15-2 928 950
702N 930
802 931-KP
802N 936-KP
ALTERNATE “D” COMPONENTS/ON-OFF SWITCH - Refer to literature for switch specifications.
Desk Switch Push Switch
15-1 ON-OFF 401 ON-OFF
NOTES: Consult factory for 3 and 4 door mantraps. Operation and configurations shown may be altered for specific job
application needs. Consult factory for more information. Component changes may require system design/schematic
changes. Consult factory. Consult factory for Control and Monitoring Panel applications.
APPLICATIONS
Darkrooms, laboratories, clean rooms, x-ray or other treatment rooms, light and air trap rooms and more.
OPERATION
All doors remain closed and unlocked. Opening either door
causes the second door to lock until the opened door returns
to the closed position. A key switch is provided for system
activation and deactivation.
SYSTEM COMPONENTS SHOWN
(A) 631RFA-UR2-INTA Power Supply
(B) 1511-DPS EmLock
(C) 701 System On-Off Key Switch
ALTERNATE “B” COMPONENTS
Refer to literature for lock specifications.
EmLocks Electric Strikes HiTower Bolt Locks
1581-DPS 51-A-LBM 7530-L FS23M-9
1565-DPS 52-B-LBM 7830-DS 1190A-9
1511-DPS-TJ 52-C-LBM 7560-L 1091A-9
Indicates Fail Secure
NOTES: Consult factory for 3 and 4 door interlocks. Operation and configurations shown may be altered for specific job
application needs. Consult factory for more information. Component changes may require system design/schematic changes.
Consult factory.
FIRE ALARM PANEL
(For Fire Safety
Application Only)
115VAC
2 DOOR INTERLOCK "A"
3 and 4 Door Interlock Available
FIRE ALARM PANEL
(For Fire Safety
Application Only)
115VAC
2 DOOR MANTRAP "B"
3 and 4 Door Mantrap Available
DOOR LAYOUT 1