7 
Attach the ground wire to one of the lower power supply mounting screws 
Note: UL regulations require that you do NOT place high voltage (120V) and low voltage 
communication cables in the same conduit or through the same knockout holes 
•  Follow the wiring steps in step 2 
•  For the cleanest installation, mount the display unit over a standard “double gang” 4-inch 
electrical box 
•  Route the other end of the 8-foot connection cable to this electrical box 
•  Place two #8 screws, 12 inches apart and level, ½-inch down from the top of the electrical box 
•  Connect the 8-foot connection cable and any communication cables to the display unit 
•  Check your connections, then turn your Master on using the On/Off switch on the power supply 
board 
•  Attach the furnished cover to the power supply using four 6-32 screws (two of these screws you 
earlier removed from the display unit) 