Operating instructions

SHERWOOD LPG PRODUCTS
Filler & Vapor Return Valves
PVE1876
FOR VALVE
See Instruction Sheet: Use Replacement Part Kit:
PVE1855 Series R-1855 1855-100-KIT
PVE623C R-623C 623C-100-KIT
PVE1876 R-1876 1876-100-KIT
ORDERING INFORMATION
Part Number Container Connection Filler Connection
*Dimensions
(Inches) Fill Rate at Various Differential Pressures (GPM Propane)
A B C Hex 10 psig 25 psig 50 psig 75 psig
PVE1855SD
3
4
" NPT 1
3
4
" ACME 2
7
64
" — 1
3
4
"19304360
PVE1855SD-30
3
4
" NPT 1
3
4
" ACME 2
19
32
"1
1
4
"1
3
4
"19304360
PVE1855SPD
3
4
" NPT
3
4
" FNPT 1
3
4
"—1
3
4
"19304360
PVE1855SVFD
3
4
" NPT
1
2
" SAE Flare 2 1
3
4
"19304360
PVE1855SD-90
3
4" NPT
1
2" SAE Flare 2 1
19
64"1
3
4"19304360
PV1855BRCN
1
2" SAE flare 1
3
4" ACME 1
5
8"19304360
PVE623C 1
1
4" NPT 1
3
4" ACME 2 1
7
8" 70 92 144 158
PVE1876
3
4" NPT 1
3
4" ACME 1
45
64"—1
1
4" At 100 psig inlet pressure, LPG flow is 3100 CFH (vertical), 2970 CFH (horizontal)
Note: For replacement components, please refer to the following chart.
PVE1876 Vapor Return Valve
t Has upper positive back check valve and
lower excess flow valve
t Attachment of the vapor hose coupling with
its projecting nozzle opens the back check
valve to permit flow in both directions
t 1876-100-KIT — see pages 58–59
A
Approximate top
of tank
C
All Safe, Inc. 1-866-958-3473