User Guide

12
NATURAL GAS CONVERSION
IMPORTANT:
After your outdoor kitchen is converted to natural gas, the working pressure for natural gas is 7
in. water column (WC). Gas pressure is affected by gas line size and the length of gas line run
from house. Follow the recommendations in the chart below.
WARNING:
Place the grill on a flat, level surface.
Before the conversion, make sure all control knobs are in the OFF position, LP tank valve is
closed, and tank is disconnected from regulator and removed from grill.
From House to Grill
Distance Tubing Size
Up to 25 ft. 3/8 in. DIA
26 – 50 ft. 1/2 in. DIA
51 – 100 ft.
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
Over 101 ft. 3/4 in. DIA
Distancia
Hasta 7,62 m
7,92 m – 15,24 m.
15,54 m –
30,48 m.
Más de 30,78 m
Tamaño de las tuberías
0,95 mm de diám.
1,27 cm de diám.
1,69 cm a 1,90 cm
0,85 cm a 1,27 cm
1,90 cm de diám.
'HVGHODFDVDKDVWDODSDUULOOD
88
CONVERSIÓN A GAS NATURAL
IMPORTANTE
'HVSXpVGHFRQYHUWLUODFRFLQDSDUDH[WHULRUHVDJDVQDWXUDOODSUHVLyQGHWUDEDMRSDUDJDVQDWXUDO
es de 17,78 cm de columna de agua (C.A.). La presión de gas se ve afectada por el tamaño y el
largo de la línea de gas proveniente de la casa. Siga las recomendaciones del siguiente cuadro.
ADVERTENCIA:
&RORTXHODSDUULOODHQXQDVXSHU¿FLHSODQD\QLYHODGD
Antes de realizar la conversión, asegúrese de que todas las perillas de control se encuentren en
la posición “OFF” (APAGADO), que la válvula del tanque de PL esté cerrada y que el tanque esté
desconectado del regulador y alejado de la parrilla.