BLG/TLG Series Bottom Mount Glass Door Merchandisers 2005 “K” Version with Dixell controller Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Service Phone: 800-684-8988 PN 303-91000 Rev:8-20-05 Rev:8-23-06
TABLE OF CONTENTS INTRODUCTION………………………………….……………………………………………………………………4 STORE CONDITIONS…………………………….……………….…..…………………………………………….. 4 WARNING LABELS AND SAFETY INSTRUCTIONS………..…..……………………………………………… 5 PRE-INSTALLATION INSTRUCTIONS………………………..…..………………………………….…………… 6 Inspection for Shipping Damage…………………………………………………………….……………... 6 INSTALLATION INSTRUCTIONS………………………………………………………………………………….. 6 General Instructions…………………………………………………………………………………………. 6 Mechanical ..…………………………………………………………………………………………………..
INTRODUCTION Thank you for purchasing a Master-Bilt cabinet. This manual contains important instructions for installing, using, and servicing a Master-Bilt BLG/TLG case. A parts list is included with this manual. Read all these documents carefully before installing or servicing your equipment. STORE CONDITIONS The Master-Bilt BLG/TLG cases are designed to operate in the controlled environment of an air-conditioned store.
WARNING LABELS AND SAFETY INSTRUCTIONS This symbol is the safety-alert symbol. When you see this symbol on your cabinet or in this manual, be alert to the potential for personal injury or damage to your equipment. Be sure you understand all safety messages and always follow recommended precautions and safe operating practices. NOTICE TO EMPLOYERS You must make sure that everyone who installs, uses or services your cabinet is thoroughly familiar with all safety information and procedures.
PRE-INSTALLATION INSTRUCTIONS INSPECTION FOR SHIPPING DAMAGE You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage is noted to shipping crates or cartons or if a shortage is found, note this on the bill of lading (all copies) prior to signing.
ELECTRICAL WARNING Before servicing electrical components in the case or the doors or door frames make sure all power to case is off. Always use a qualified technician. Check voltage and amps drawn on (Page 17-20) to determine proper line and fuse or circuit breaker size. Check power supply for low voltage. If voltage reads “230” with no load, and it drops below “207” when the compressor tries to start, it is an indication of too small supply wiring or too long to run.
DOORS The BLG/TLG cabinets have Anthony glass doors that are equipped with a patented TorqueMaster™ hinge system. The doors are easily adjusted using a flathead screwdriver (Fig.3). * The tension needs to be checked and set when first install. Leveling Adjustment Torque Adjustment Figure 3 To remove the door shipping clamps, remove the 4 shipping screws from the grill and remove the screws from the clamps (Fig.4), and replace grill.
MASTER-BILT ELECTRONIC REFRIGERATION CONTROL OPERATION Compressor When power is first turned on to the control, the LED indicator under COMP on the display starts blinking. After one-minute delay the compressor comes on. The COMP LED indicator stays on while compressor relay is energized. Display will show actual box temperature. Figure 4 is the display layout. The compressor will be cycled off when the actual box temperature reaches its set point. The COMP indicator will be off. Fig.
HOW TO CHANGE THE SETPOINT 1. Push the SET key for more than 2 seconds to change the Set point value; 2. The value of the set point will be displayed and the LED under COMP starts blinking; 3. To change the Set value push the UP ▲ or DOWN▼ arrows within 10s. To memorize the new set point value push the SET key again or wait 10s. HOW TO CHANGE a parameter value 1. Enter the Programming mode by pressing the SET and DOWN ▼ keys for 3 seconds (LEDs under DEF and COMP start blinking). 2.
ALARM SIGNALS Message Cause Room probe failure “P1” Outputs Compressor output time, 6 min on, 4 min off “P2” Evaporator probe failure Defrost end is timed “HA” Maximum temperature alarm Outputs unchanged. “LA” Minimum temperature alarm Outputs unchanged. NOTE: Probe alarms “P1” and “P2” start some seconds after the fault in the related probe; they automatically stop some seconds after the probe restarts normal operation. Check connections before replacing the probe.
FINAL CHECK LIST A. Check operating pressures. B. Check electrical requirements of unit to supply voltage. C. Set temperature control for desired temperature range. D. Check sight glass for proper refrigerant charge, if provided. E. Check system for proper defrost settings and operation. F. Check condensing unit for vibrating or rubbing tubing. Dampen and clamp as required. G. All valves should be completely opened counter-clockwise. H. Check packing nuts on all service valves. I.
Temperature sensor, defrost heater and fan motor replacement Before making any change, technician should: 1. Disconnect power to the cabinet 2. Remove screws from venturi and pull down To change a temperature sensor (cabinet zone sensor or defrost termination sensor), simply disconnect the sensor wires from the controller and replace the new sensor in the original position. Use plastic tie to tighten the zone sensor.
MASTER-BILT PART LIST The table below gives Master-Bilt part numbers. Use this chart when ordering replacement parts for your BLG/TLG cabinets.
Accessories (Includes HD Models) Description Baskets (Cantilever) 20” X 22” X 5” Baskets (Conventional) 22”X 22-3/4”X 5” Baskets (Conventional) 24-3/4”X22”X5” Casters (4) 3” Diameter Casters (6) 3” Diameter Legs 6” Shelves (Cantilever) Shelve, Bottom Shelving Clips (4) BLG/TLG27HD BLG/TLG48HD BLG/TLG52HD BLG/TLG74HD 33-01458 33-01458 33-01419 33-01419 33-01376 A200-11140 A200-11170 33-01473 33-01402 33-01011 A200-11140 A200-11170 33-01474 33-01453 33-01011 BLG/TLG80HD 33-01376 A200-11140 A20