Troubleshooting Guide
VT-751D and VT-752D 
Master Appliance Corp. 
2420 18
th
 St. 
Racine, WI 53403-2381 USA 
Tel: 262-633-7791 
Email: sales@masterappliance.com 
www.masterappliance.com 
58279E REV A 
pg. 4 of 7 
Figure 7 
SHRINK TUBE MUST COVER 
TERMINALS OF WHITE WIRE FROM 
CORDSET, MOTOR AND ELEMENT 
HOLDER, 
SHRINK TUBE, 
MOVE TO COVER 
TERMINALS 
Ⓣ 
ELEMENT 
HOLDER 
BLACK WIRES MUST 
CLEAR SCREW 
BOSSES 
To remove the element connector: 
1.  Disconnect the black lead wire of the element connector from 
circuit board (Figure 5). Disconnect the white lead wire of the 
element connector (with piggyback terminal) from both the white 
wire of the motor and the white wire of the cordset (Figure 3). 
To remove the cordset: 
1.  Remove the green ground screw located near the nozzle of the 
housing (Figure 1). Remove the black cordset wire from the 
piggyback terminal of the jumper, (Figure 6). Remove the white 
cordset wire from the piggyback terminal on the white wire from 
the element connector (Figure 3). Lift the cable guard out of the 
handle and remove the cordset. 
INSTALLATION INSTRUCTIONS 
To install the new CIRCUIT BOARD: 
1.  Place the circuit board into the housing with the knurled stem 
protruding through the hole at the bottom of the housing 
(Figure 7).  
2.  Assemble the #6-32 pan head screws Ⓜ (2 screws) to retain the 
circuit board, and tighten to 12 – 15 in-lbs torque (Figure 1). 
3.  Connect the terminal of the black wire from the new circuit board 
to the switch Ⓝ (Figure 8).  
4.  Assemble the new shrink tube Ⓣ over the black wire from the 
element connector (Figure 5 & 7). 
5.  Connect the black wire from the new circuit board to the black 
wire from the element holder Ⓟ. The new shrink tube Ⓣ must 
be positioned over the terminals (Figure 5).  
To install the MOTOR: 
1.  Ensure the black motor wire is connected to the switch Ⓢ 
(Figure 8).  
2.  Connect the white motor wire to the piggyback terminal of the 
white element connector wire and white wire from cordset 
(Figure 3). 
3.  Assemble motor into housing and with (2) #6-32 x .50 long 
screws Ⓛ (Figure 1). Torque to 16 – 20 in-lbs. 
4.  Assemble (1) M3 x 0.5 Ⓚ (Figure 2) through back side of 
housing and into motor frame at a torque of 2-5 in-lbs. 
Excessive torque will warp the motor frame, resulting in reduced 
air flow and damage to the motor. 
5.  Assemble blower wheel onto shaft of motor and tighten set 
screw with 1/8 inch hex key. Top of blower wheel hub must be 
flush with top of motor shaft. Must not rub against frame of 
motor and must not rub against wiring (Figure 9). 
To install the ELEMENT CONNECTOR: 
1.  Connect the black wire from the new element connector to the 
black wire from the circuit board Ⓟ. The new shrink tube Ⓣ 
must be positioned over the terminals (Figure 5). 
2.  Connect the white wire of the element connector to the white 
wires from the motor and cordset (Figure 10).  Position the 
shrink tube over the terminal from the motor and from the 
cordset after the terminals are connected. 
 WARNING: Failure to cover the terminals with 
 shrink tubing 
Ⓣ
 could result in electrical short 
SWITCH 
TERMINALS 
CIRCUIT BOARD 
BLACK WIRE 
MOTOR 
BLACK WIRE 
Ⓢ 
JUMPER 
BLACK WIRE 
BLACK 
JUMPER 
WIRE 
Figure 8 
Ⓝ 
Figure 9 
SHAFT FLUSH WITH 
TOP OF FAN HUB 
 WARNING: Failure to cover the terminals with 
 shrink tubing 
Ⓣ
 could result in electrical short 
 WARNING: Failure to cover the terminals with 
 shrink tubing could result in electrical short 
Figure 6 
BLACK CORDSET 
WIRE 