Specifications
Chapter 10: S6 Channel Modules 97
Clear (Reset to Default)
You can quickly reset faders, individual parameters, functions, or entire tracks to their default values using the Clear switch, lo-
cated at the top of each strip on the Process Module.
To clear:
1 Press Clear on the desired strip. Its LED flashes red, and switches for all functions available to be reset are lit.
2 While Clear is engaged (flashing) do any of the following:
• To reset a fader unity (0 dB on the strip), press
F on the Fader Module or touch the fader.
• To reset an individual parameter, press its knob top.
• To reset a function, press the desired function switch in that strip (such as
EQ, Dyn, or Pan). Not all functions support Clear.
• To reset an entire strip, press the strip
Select switch on the Fader Module.
The parameter or function resets and the
Clear switch stops flashing and remains unlit.
Expand
Expand mode maps parameters beyond the current strip, expanding (or “spilling”) EQ, dynamics, or other functions across multiple
controls on Knob Module(s). Expand mode uses Knob Modules in the same chassis as the track.
To enable Expand mode on a strip:
1 Press Exp on the Process Module (see Figure 60). Multiple strips can be in Expand mode simultaneously.
The most recently selected strip/function is expanded, and selecting a different function on a strip in Expand mode replaces the
currently expanded function view. When enabled, the
Exp switch LED lights orange. Only the currently expanded function LED
is lit in the Process Module, letting you quickly identify what is being viewed. If multiple strips are in Expand mode the inactive
Expand keys light yellow.
2 If more parameters are available than there are controls, the <PAGE> switches light on strip 8; press either to navigate to other
parameters.
• When enabled in a chassis with one or more Knob Modules, Expand mode takes over either or both Knob Modules (depending
on the number and mapping of parameters in the current function).
3 To take a strip out of Expand mode, press its lit Exp switch.
To put all strips into Expand mode simultaneously, press the All switch (on the Master Module) before pressing Expand. The All
switch is latching, so press it again to disable All mode (the switch becomes unlit).
Figure 60. Exp (Expand) switch on the Process Module