Specifications

tecal portable dri-block
®
calibrators
12
TechneWorks
Techne are pleased to announce the introduction of our FREE OF CHARGE, easy to use Control
software for many of our RS-232 compatible products.This software has been designed to
supersede the existing Calsoft and Thermsoft software packages.
It will allow customers to carry out all the tasks previously available on Calsoft and Thermsoft plus
many new options on one new package. It is fully compatible with all Techne RS-232 Calibration
products including all current models and older discontinued models such as the TU-20C.
Compatible units are as follows:-
Dri-Block Calibrators - Tecal H, S and F models
- New Tecal 1200S High temperature furnace
Thermoregulators - TU-20D and TU-20HT (and TU-20C)
Precision Digital Thermometer - Accu-Temp with RS-232 communication option
Fluidised Baths - FB-08C and TC-8D with RS-232 communication option
TechneWorks software allows connection to a range of Precision Thermometers such as the
Techne Accu-Temp, ASL model F250, Accu-TempII and the Cropico 3000 series. TechneWorks
software enables you to calibrate thermometers and sensors and to then generate calibration
certificates using a Techne Liquid bath or Dry block as a temperature source. The Calibration
bath or Dri-Block’s display can act as the reference temperature or connect to a range of external
thermometers.
Software Features
ALL MODELS
Create, open and save programs with up to 20 set points.
Specify either °C or °F.
Specify ramp rates and hold times.
Log data from the instrument while connected to the computer and export the data in an
Excel spreadsheet.
Open, save, view and print logged data.
Perform a calibration where temperature of the probe is manually entered.
Perform an automatic calibration routine where the temperature reference probes data is
added automatically.
Run a program in real time mode.
Specifying the logging interval from every 5 seconds to 60 seconds
Set ramp rates from 0.1 to 10.0ºC/min
TECAL H MODELS ONLY has above features plus the following:-
Perform a calibration using the User Probe Interface
Perform a calibration requiring a switch test
Send programs to the calibrator
Retrieve programs from the calibrator
Retrieve test results from the calibrator
Erase test results
(downloadable free of charge from
www.techne.com and www.techne-calibration.com)
Note: CD with software included with Tecal H and TU-20HT models
The TechneWorks software is available as a Factory enabled version which allows re-Calibration of
our Tecal Calibrators. This supersedes the Factory Calsoft software.
Utilities button is only available on enabled version.