Specifications
38
industrial uidized baths
AB100 Afterburner
Model AB100 is designed to reduce smoke emission from the exhaust gas ue of most all Techne
uidized bath cleaning systems. The Afterburner consists of a burner plate mounted within a
thermally insulated combustion chamber. The input to the combustion chamber is designed to mate
directly to a standard Techne extraction fan, while the output is suitable for connection to an exhaust
stack.
The AB100 will not remove hydrogen chloride from exhaust gases. The SR100 fume scrubber should
be placed before the afterburner whenever considerable quantities of HCL will be generated.
AB100
Overall size (H x W x D) in. 98.4 x 47.2 x 39.4”
Burner rating 3kW to 60kW; 10,000 BTU/hr to 200,000 BTU/hr
Fuel consumption range
Natural gas 10 to 200 ft
^3/hr
Butane 3 to 60 ft
^3/hr
Propane 4.5 to 90 ft
^3/hr
Gas supply pressure
Natural gas 6 to 10 inch WG
Butane 10 to 14 inch WG
Propane 10 to 14 inch WG
Voltage supply required 220/240V 1Ph 50/60Hz
Exhaust gas temperature Typically 450°C/842°F
Outlet spigot 8.0”
Shipping weight (lbs) 125
Catalog number FSAB1
Technical Speci cations
AB100
SR100 Scrubber
The Techne Venturi Fume Scrubber removes water soluble constituents in the e uent gasses from the
Techne Industrial Fluidized Baths which would not be removed in the optional Afterburner. The unit
is designed to reduce concentrations of Hydrogen Halides (Chloride and Fluoride) produced by the
decomposition of Halogenated polymers such as PVC and PTFE.
The SR100 removes 95% of HCL in the exhaust gas so that as long as the scrubber is not overloaded
by burning o too large a quantity of PVC the emerging gasses will contain a quantity of HCL low
enough to be safely vented to the atmosphere.
It is recommended that a Techne Cyclone be tted before the scrubber to avoid unnecessary loss of
medium and loading of the scrubber with particulates.
SR100
Overall size (H x W x D) in. 73 x 17.7 x 17.7”
Scrubbing capacity HCL from 8kg/hr of PVC
Make up water requirements 10 gallons/hr
Discharge limits HCL 0.2 grains/ft^3
Air ow 2.8 to 7.0 m^3/min
Exhaust gas temperature Typically 450°C/842°F
Inlet spigot 4.0”
Outlet spigot 4.0”
Water inlet 1/2” BSP
Voltage supply required 220/240V 1Ph 50/60Hz
Shipping weight (lbs) 60
Catalog number FSSR1
Technical Speci cations
SR100