Operating instructions
Regency
®
PG36-3 Gas Log Fireplace
6
INSTALLATION
Min. 6"
(152mm)
Min. 8"
(203mm)
30-1/2" (775mm)
Top of Unit
Min. 32" (1016mm)
to Ceiling"
Clearances for Bay or Flush Front
Clearances for Barcelona Front
NOTE: The minimum fl oor clearance must
be maintained from the top surface of the
carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel* Minimum 7" (177mm)
Ceiling from top of unit. 32" (1016mm)
Side Wall Clearance
Bay or Flush Front 6" (152mm)
Barcelona Front 8" (203mm)
Horizontal Flue Clearances
Top 2" (51mm)
Side 1-1/2" (38mm)
Bottom 1-1/2" (38mm)
Vertical Flue Clearances 1-1/4" (32mm)
Alcove Clearances**:
Max. Depth 36" (914mm)
Min. Width 48" 1219mm)
Min. Height 72" 1829mm)
* see mantle clearance instructions
(Refer to the "Combustible Mantels," & "Mantel
Leg Clearances" sections.)
**Approved for one sidewall installation
only when using Barcelona Front.
CLEARANCES
The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fi res is
failure to maintain required clearances (air
space) to combustible materials. It is of the
greatest importance that this fi replace and
fl ue system be installed only in accordance
with these instructions.
Clearance to Combustibles from:
Back 0" (0mm)
Side 0" (0mm)
Floor 0" (0mm)
Diagram 1
LOCATING YOUR
FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for
servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The PG36 Co Axial Flue Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. Refer to the "Wiring"
section.
A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The PG36 Co Axial Flue Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on this page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and fl oor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For flue terminations see the
"Exterior Flue Termination Locations"
section.
WARNING
Fire hazard is an extreme
risk if these clearances
are not adhered to.
For more Barcelona Framing and Installation
Notes, see the "Framing and Finishing"
section.
BARCELONA FRAMING NOTE: If the
Barcelona Trim is to be installed, the front
face of the fi replace must be made of non-
combustible material. See Diagram 1.
Diagram 1