User's Manual
Table Of Contents
- About this Manual
- Product Description, Features and Indications for Use
- Safety Information, Warnings and Cautions
- Chapter 1- Technology Overview
- Signal Extraction Technology® (SET®)
- rainbow Pulse CO-Oximetry Technology
- rainbow Acoustic Monitoring™ (RAM™)
- In Vivo Adjustment™
- Signal IQ® (SIQ)
- Adaptive Threshold Alarm (ATA)
- FastSat® (FST®)
- Sensitivity Modes
- Chapter 2- System Components
- Chapter 3- Setup
- Chapter 4- Operation
- Chapter 5- Alarms and Messages
- Chapter 6- Troubleshooting
- Chapter 7- Specifications
- Measurement Range
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Alarms
- Display Indicators
- EMC Compliance
- Safety Standards Compliance
- Radio Compliance
- Guidance and Manufacturer's Declaration- Electromagnetic Emissions
- Guidance and Manufacturer's Declaration- Electromagnetic Immunity
- Recommended Separation Distances
- Symbols
- Citations
- Chapter 8 - Service and Maintenance
- Appendix
- Index
Radius-7 Chapter 4- Operation
www.masimo.com 43 Masimo
Navigating Radius-7 Settings on Root
The following settings on Radius-7 can be configured with Root:
• Sensitivity Mode settings
• Parameter Alarm settings
• In vivo settings
• Additional settings including Averaging time and FastSat.
The following section describes how Radius-7 settings may be configured with Root when
connected via Bluetooth. See Connecting Radius-7 to Root via Bluetooth on page 36 of the
Operator’s Manual for information on how to pair Radius-7 with Root. For general information
on Root, see Operator’s Manual for Root
Configuring Sensitivity Modes
There are two ways to access sensitivity settings menu on Root:
1. From the Main Screen on Root, press on the Sensitivity icon displayed on the top
of the screen to toggle through sensitivity configuration options.
Or
2. Press the gear icon on the bottom right-hand corner of the Main Screen on Root to
access the Main Menu, press the Rainbow tile to access the Rainbow menu. In the
Rainbow menu select the Additional Settings tile to select Sensitivity Mode.
Options Description Factory
Default
Configuration
Options
Sensitivity
Modes
Defines the sensitivity level for which
the device will operate. See Sensitivity
Modes on page 30 of the Operator's
Manual.
APOD MAX, APOD, or
NORM
Configuring Parameters
Each parameter displayed on Root and Radius-7 can be configured in its respective menu on
Root. Configurable options include Alarm Settings, In Vivo Adjustment, and Averaging Time.
There are two ways to access any parameter’s settings menu on Root:
1. From the Main Screen on Root, press on any of the parameters displayed in the
rainbow window to access its respective settings menu.
Or
2. Press the gear icon on the bottom right-hand corner of the Main Screen on Root to
access the Main Menu. Then press the Rainbow tile to access the Rainbow menu.