User's Manual
Table Of Contents
- About this Manual
- Product Description, Features and Indications for Use
- Safety Information, Warnings and Cautions
- Chapter 1- Technology Overview
- Signal Extraction Technology® (SET®)
- rainbow Pulse CO-Oximetry Technology
- rainbow Acoustic Monitoring™ (RAM™)
- In Vivo Adjustment™
- Signal IQ® (SIQ)
- Adaptive Threshold Alarm (ATA)
- FastSat® (FST®)
- Sensitivity Modes
- Chapter 2- System Components
- Chapter 3- Setup
- Chapter 4- Operation
- Chapter 5- Alarms and Messages
- Chapter 6- Troubleshooting
- Chapter 7- Specifications
- Measurement Range
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Alarms
- Display Indicators
- EMC Compliance
- Safety Standards Compliance
- Radio Compliance
- Guidance and Manufacturer's Declaration- Electromagnetic Emissions
- Guidance and Manufacturer's Declaration- Electromagnetic Immunity
- Recommended Separation Distances
- Symbols
- Citations
- Chapter 8 - Service and Maintenance
- Appendix
- Index
www.masimo.com 11 Masimo
Safety Information, Warnings and
Cautions
CAUTION: Radius-7 Wearable Pulse CO-Oximeter is to be operated by, or under the
supervision of, qualified personnel only. The manual, accessories, directions for use, all
precautionary information, and specifications should be read before use.
Safety Warnings and Cautions
WARNING: Do not use Radius-7 if it appears or is suspected to be damaged.
WARNING: Always use Radius-7 in conjunction with Root. Do not use parts from other
systems. Injury to personnel or equipment damage could occur.
WARNING: Do not adjust, repair, open, disassemble, or modify the Radius-7. Injury to
personnel or equipment damage could occur.
WARNING: Do not start or operate the Radius-7 unless the setup was verified to be correct.
WARNING: To ensure safety, only use Masimo authorized devices with Radius-7.
WARNING: All sensors and cables are designed for use with specific devices. Verify the
compatibility of the device, cable, and sensor before use; otherwise degraded performance
and/or patient injury can result.
WARNING: Explosion Hazard: Do not use the Radius-7 in the presence of flammable
anesthetics or other flammable substance in combination with air, oxygen-enriched
environments, or nitrous oxide.
WARNING: Do not use the Radius-7 during magnetic resonance imaging (MRI) or in an MRI
environment.
WARNING: Radius-7 may be used during defibrillation. However, to reduce the risk of electric
shock, the operator should not touch the Radius-7 during defibrillation.
WARNING: Electrical Shock Hazard: To protect against injury, follow the directions below:
• Avoid placing the device on surfaces with visible liquid spills.
• Do not soak or immerse the device in liquids.
• Do not attempt to sterilize the device.
• Use cleaning solutions only as instructed in this Operator's Manual.
• Do not attempt to clean the Radius-7 while monitoring patient.