User's Manual
Table Of Contents
- About this Manual
- Product Description, Indications for Use, Contraindications, and Features
- Safety Information, Warnings, and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screenlock
- Using the Home Button
- Navigating the Radical-7
- About the Display View
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Sounds
- Device Settings
- Trends
- About
- Chapter 5: Configurations
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold Alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Service Required Message
- Incompatible Cable Message
- Chapter 7: Troubleshooting
- Troubleshooting Measurements
- Signal Indication and Quality Indicator (SIQ)
- Dimly Lit Parameters
- Low Perfusion
- Low Signal Quality
- SpO2 Values Do Not Correlate With Clinical Assessment or Arterial Blood Gas Measurements
- Unexpected SpO2, SpCO, SpMet, or SpHb Reading
- Unexpectedly High SpCO Reading
- Difficulty Obtaining a Reading
- SpCO Reading Displays as Dashes
- Troubleshooting the Radical-7
- Troubleshooting Measurements
- Chapter 8: Specifications
- Performance
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Trending
- Alarms
- Display Indicators
- Compliance
- Output Interface
- Wireless Radio (If Installed)
- Serial Interface Specifications
- Serial Interface Setup
- Analog Output and Nurse Call Specifications
- Symbols
- ISO Country Codes (FCC and EU)
- Citations
- Chapter 9: Service and Maintenance
- Appendix: Best Practices for Comparisons to Reference Measurements
- Index
Radical-7 Product Description, Indications for Use, Contraindications, and Features
www.masimo.com 10 Masimo
Signal IQ waveform for signal identification and quality indication during
excessive motion and low signal to noise situations.
FastSat tracks rapid changes in arterial O2.
Variable pitch provides tonal variance for every 1% change in saturation.
SatShare interface allows transfer of SpO2 and pulse rate to an existing
multi-parameter monitor and allows for the reading of SpCO, SpMet, SpHb, and
SpOC on the monitor.
Automatic screen rotation provides upright display for vertical or horizontal
monitor positioning.
Multi-gesture touchscreen interface.
Detachable portable Handheld for patient transport.
Desat Index Alarm may help clinicians to detect an increasing quantity of smaller
desaturations that may precede declining respiratory status.
Perfusion Index (PI) Delta Alarm alerts clinicians to possible changes in
perfusion, often a reliable indicator of illness severity.
Advanced Threshold Alarms to dynamically adjust alarm thresholds that are
tailored specifically to the patient.
Remote alarm interface.
Indications for Use
The Masimo Radical-7 and accessories are indicated for the continuous noninvasive
monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate,
carboxyhemoglobin saturation (SpCO), methemoglobin saturation (SpMet), total
hemoglobin concentration (SpHb), and/or respiratory rate (RRa).
The Masimo Radical-7 and accessories have been validated and are indicated for use with
adult, pediatric, and neonatal patients during both no motion and motion conditions, and
for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and
home environments.
In addition, the Masimo Radical-7 and accessories are indicated to provide the continuous
noninvasive monitoring data obtained from the Masimo rainbow SET Radical 7 Pulse
CO-Oximeter and accessories of functional oxygen saturation of arterial hemoglobin (SpO2)
and pulse rate to multi-parameter devices for the display of those devices.
Contraindications
The Radical-7 is not intended for use as an apnea monitor.