User's Manual
Table Of Contents
- About this Manual
- Product Description, Indications for Use, Contraindications, and Features
- Safety Information, Warnings, and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screenlock
- Using the Home Button
- Navigating the Radical-7
- About the Display View
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Sounds
- Device Settings
- Trends
- About
- Chapter 5: Configurations
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold Alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Service Required Message
- Incompatible Cable Message
- Chapter 7: Troubleshooting
- Troubleshooting Measurements
- Signal Indication and Quality Indicator (SIQ)
- Dimly Lit Parameters
- Low Perfusion
- Low Signal Quality
- SpO2 Values Do Not Correlate With Clinical Assessment or Arterial Blood Gas Measurements
- Unexpected SpO2, SpCO, SpMet, or SpHb Reading
- Unexpectedly High SpCO Reading
- Difficulty Obtaining a Reading
- SpCO Reading Displays as Dashes
- Troubleshooting the Radical-7
- Troubleshooting Measurements
- Chapter 8: Specifications
- Performance
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Trending
- Alarms
- Display Indicators
- Compliance
- Output Interface
- Wireless Radio (If Installed)
- Serial Interface Specifications
- Serial Interface Setup
- Analog Output and Nurse Call Specifications
- Symbols
- ISO Country Codes (FCC and EU)
- Citations
- Chapter 9: Service and Maintenance
- Appendix: Best Practices for Comparisons to Reference Measurements
- Index
Radical-7 Chapter 6: Alarms and Messages
www.masimo.com 101 Masimo
Replace Cable Message
Message:
(Pulse Ox) Replace Cable
(RAM) Replace Cable
The patient cable is non-functional or the life of the cable has expired.
Next steps: Replace the patient cable.
Replace Adhesive Sensor Message
Message:
(Pulse Ox) Replace Adhesive Sensor
(RAM) Replace Adhesive Sensor
When a single-patient-use sensor is used, the adhesive portion of the sensor is
non-functional, or the life of the adhesive portion of the sensor has expired. (Applies to
Rainbow ReSposable CO-Oximeter Sensor Systems or ReSposable Pulse Oximeter Sensor
Systems only.)
Next steps: Replace the adhesive portion of the sensor.
Incompatible Sensor Message
Message:
(Pulse Ox) Incompatible Sensor
(RAM) Incompatible Sensor
Not a proper Masimo sensor.
Next steps: Replace with a proper Masimo sensor.
SpHb sensor is attached to a instrument without SpHb installed.
Next steps: Use a non-SpHb sensor. Contact your local Masimo Representative to learn
more about the optional SpHb upgrade.
Incompatible Adhesive Sensor Message
Message:
(Pulse Ox) Incompatible Adhesive Sensor
(RAM) Incompatible Adhesive Sensor
Not a proper Masimo sensor.
Next steps: Replace with a proper Masimo sensor.
SpHb sensor is attached to a instrument without SpHb installed.
Next steps: Use a non-SpHb sensor. Contact your local Masimo Representative to learn
more about the optional SpHb upgrade.