Operator's Manual
Table Of Contents
- About this Manual
- Product Description
- Indications for Use
- Contraindications
- Warnings and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology®
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- General Description for Oxygen Reserve Index (ORI)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screen Lock
- Using the Home Button
- Standby and Power Off
- Navigating the Radical-7
- About the Display View
- Sensitivity Modes Overview
- Changing Sensitivity Modes
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Chapter 5: Profiles
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- RAM Check Sensor Message
- RAM Sensor Initializing Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- Invalid Parameter Alarm Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Incompatible Cable Message
- Near Expiration Message
- Chapter 7: Troubleshooting
- Chapter 8: Specifications
- Chapter 9: Service and Maintenance
- Appendix
- Index
Radical-7 Warnings and Cautions
www.masimo.com 17 Masimo
under any circumstances remove the grounding conductor from the
power plug.
Caution: Only use the AC power cable provided by Masimo. Using a
different AC power cable could cause damage to Radical Docking Station.
Check the power cord and plug to ensure that it is intact and
undamaged.
Caution: To ensure patient electrical isolation, all external device
connections to the Analog Output/Nurse Call connector must be IEC-
60950 compliant.
Caution: To ensure patient electrical isolation, all external device
connections to the RS-232 serial port must be IEC-60950 compliant.
Note: If there is any doubt about the integrity of the protective earth
conductor arrangement, operate the Radical-7 on internal battery power
until the AC power supply protective conductor is fully functional.
Note: Disconnect the device from AC mains by removing the AC power
cord connector from the appliance inlet.
Performance Warnings and Cautions
Warning: Radical-7 is not an apnea monitor.
Warning: Radical-7 should not be used for arrhythmia analysis.
Warning: Radical-7 may be used during defibrillation, but this may affect
the accuracy or availability of the parameters and measurements.
Warning: Radical-7 may be used during defibrillation; however, the
display may require up to 15 seconds to return to normal operation.
Warning: Radical-7 may be used during electrocautery, but this may
affect the accuracy or availability of the parameters and measurements.