User's Manual
Table Of Contents
- About this Manual
- Product Description, Indications for Use, Contraindications, and Features
- Safety Information, Warnings, and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology (SET)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring (RAM) Technology
- Chapter 2: Radical-7 Descriptions
- Chapter 3: Setup
- Chapter 4: Operation
- Using the Touchscreen and Buttons
- Using Screen Lock
- Using the Home Button
- Navigating the Radical-7
- About the Display View
- Sensitivity Modes Overview
- Changing Sensitivity Modes
- Accessing the Main Menu
- Navigating the Main Menu
- Parameter Settings
- Sounds
- Device Settings
- Trends
- About
- Chapter 5: Profiles
- Chapter 6: Alarms and Messages
- About Alarms
- Silencing the Alarms
- Adaptive Threshold Alarm (ATA) Feature
- 3D Alarms
- Messages
- Replace Sensor Message
- Replace Cable Message
- Replace Adhesive Sensor Message
- Incompatible Sensor Message
- Incompatible Adhesive Sensor Message
- No Adhesive Sensor Connected Message
- Interference Detected Message
- SpO2 Only Mode Message
- Low Battery Message
- Low Perfusion Index Message
- Low Signal IQ Message
- Low SpCO SIQ Message
- Low SpMet SIQ Message
- Low SpHb SIQ Message
- Speaker Failure Message
- No Cable Connected Message
- No Sensor Connected Message
- Pulse Search Message
- Sensor Initializing Message
- Sensor Off Patient Message
- Incompatible Cable Message
- Chapter 7: Troubleshooting
- Chapter 8: Specifications
- Measurement Range
- Accuracy
- Resolution
- Electrical
- Environmental
- Physical Characteristics
- Trending
- Alarms
- Display Indicators
- Compliance
- Output Interface
- Wireless Radio (If Installed)
- Serial Interface Specifications
- Serial Interface Setup
- Analog Output and Nurse Call Specifications
- Symbols
- Country Codes (FCC and EU)
- Citations
- Chapter 9: Service and Maintenance
- Appendix: Best Practices for Comparisons to Reference Measurements
- Index
Radical-7 Chapter 2: Radical-7 Descriptions
www.masimo.com 34 Masimo
Functionality of the Radical-7
The Radical-7 provides the functionality of three instruments in one:
Handheld Pulse CO-Oximeter
The Radical-7 is a fully featured Handheld.
The Handheld contains the majority of the device features. All
measurements and instrument status datum are displayed on the
touchscreen. All user input is performed through the touchscreen and
control buttons. The sensor cable connector is located on the
Handheld.
Standalone Pulse Oximeter
The Radical-7 is a fully featured Standalone Pulse-Oximeter, and Acoustic Monitor.
The Handheld snaps into the Docking Station to
provide a fully featured standalone monitor. The
Docking Station connects to AC power for
standalone operation or charging of the
Handheld. An optional Docking Station battery is
available. The Standalone features Nurse Call,
analog output, and serial output.
Monitor Interface
The Radical-7 interfaces to the SpO2 input module of multi-parameter patient monitors to
upgrade conventional pulse oximetry technology on the multi-parameter monitor to Masimo
SET technology.
Utilizing a SatShare cable, the standalone
Radical-7 also interfaces with the SpO2 input of a
validated multi-parameter patient monitor,
instantly upgrading the conventional pulse
oximetry to Masimo SET pulse oximetry. The
SatShare cable attaches to the back of the Radical
Docking Station, and SatShare cables are
available to interface with most multi-parameter
patient monitors.