Operator's Manual
Table Of Contents
- About This Manual
- Product Description, Features and Indications for Use
- Safety Information, Warnings and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology® (SET®)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for SpOC
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- General Description for Respiration Rate (RRp)
- General Description for Oxygen Reserve Index (ORi)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring™ (RAM™)
- Chapter 2: Description
- Chapter 3: Setting Up
- Chapter 4: Operation
- Using the Touchscreen and Home Button
- About the Main Screen
- About the System Status Light
- Accessing Main Menu Options
- rainbow Parameter Settings
- Parameter Settings
- Temperature Settings
- Noninvasive Blood Pressure (NIBP) Settings
- NomoLine Capnography Settings
- Sounds
- Device Settings
- About
- Trends
- Call
- Rad-97 Screenshot Capture
- Patient Admit/Discharge
- EMR Push
- Chapter 5: Profiles
- Chapter 6: Temperature
- Chapter 7: Noninvasive Blood Pressure (NIBP)
- Chapter 8: NomoLine Capnography
- Chapter 9: Video Conferencing
- Chapter 10: Admit to and Discharge from Patient SafetyNet
- Chapter 11: Electronic Medical Records (EMR) Push
- Chapter 12: Third-Party Devices
- Chapter 13: Alarms and Messages
- Chapter 14: Troubleshooting
- Chapter 15: Specifications
- Pulse CO-Oximetry Specifications
- Temperature Specifications
- Noninvasive Blood Pressure (NIBP) Specifications
- NomoLine Capnography Specifications
- Electrical
- Environmental
- Physical Characteristics
- Alarms
- Display Indicators
- Compliance
- Connectors
- Wireless Specifications
- Guidance and Manufacturer's Declaration-Electromagnetic Emissions
- Guidance and Manufacturer's Declaration-Electromagnetic Immunity
- Recommended Separation Distances
- Symbols
- Citations
- Chapter 16: Service and Maintenance
- Appendix: Concepts of Alarm Response Delay
- Index
Rad-97 Chapter 15: Specifications
www.masimo.com 188 Masimo
Environmental Conditions
Non-NIBP and Non-NomoLine Capnography
models
10% to 95%, non-condensing
NIPB and NomoLine Capnography models 15% to 95%, non-condensing
Storage/Transport Humidity
Non-NIBP and Non-NomoLine Capnography
models
10% to 90%, non-condensing
NIPB and NomoLine Capnography models 15% to 90%, non-condensing
Operating Atmospheric Pressure 540 mbar to 1,060 mbar (540 hPa to 1060
hPa)
Physical Characteristics
Physical Characteristics
Dimensions 22.9 cm x 10.2 cm x 16.5 cm
(9” x 4” x 6.5”)
Weight
Without NIBP or NomoLine Capnography Approx. 0.91 kg. (2.0 lbs.)
With NIBP Approx. 1.04 kg. (2.3 lbs.)
With NomoLine Capnography Approx. 1.0 kg. (2.2 lbs.)
Alarms
Alarm
Priority
Alarm Status
Color
Audio Alarm Description
High Priority
Flashing red 571 Hz tone, 10-pulse burst, pulse spacing: 0.25s, 0.25s,
0.50s, 0.25s, repeat time:10s
Medium
Priority
Flashing yellow 550 Hz tone, 3-pulse burst, pulse spacing: 0.375s, 0.375s,
repeat time: 7s